首页 | 本学科首页   官方微博 | 高级检索  
     


A protocol for quantifying cardiogenic oscillations in dynamic 129Xe gas exchange spectroscopy: The effects of idiopathic pulmonary fibrosis
Authors:Elianna A. Bier  Scott H. Robertson  Geoffry M. Schrank  Craig Rackley  Joseph G. Mammarappallil  Sudarshan Rajagopal  H. Page McAdams  Bastiaan Driehuys
Abstract:The spectral parameters of hyperpolarized 129Xe exchanging between airspaces, interstitial barrier, and red blood cells (RBCs) are sensitive to pulmonary pathophysiology. This study sought to evaluate whether the dynamics of 129Xe spectroscopy provide additional insight, with particular focus on quantifying cardiogenic oscillations in the RBC resonance. 129Xe spectra were dynamically acquired in eight healthy volunteers and nine subjects with idiopathic pulmonary fibrosis (IPF). 129Xe FIDs were collected every 20 ms (TE = 0.932 ms, 512 points, dwell time = 32 μs, flip angle ≈ 20°) during a 16 s breathing maneuver. The FIDs were pre‐processed using the spectral improvement by Fourier thresholding technique (SIFT) and fit in the time domain to determine the airspace, interstitial barrier, and RBC spectral parameters. The RBC and gas resonances were fit to a Lorentzian lineshape, while the barrier was fit to a Voigt lineshape to account for its greater structural heterogeneity. For each complex resonance the amplitude, chemical shift, linewidth(s), and phase were calculated. The time‐averaged spectra confirmed that the RBC to barrier amplitude ratio (RBC:barrier ratio) and RBC chemical shift are both reduced in IPF subjects. Their temporal dynamics showed that all three 129Xe resonances are affected by the breathing maneuver. Most notably, several RBC spectral parameters exhibited prominent oscillations at the cardiac frequency, and their peak‐to‐peak variation differed between IPF subjects and healthy volunteers. In the IPF cohort, oscillations were more prominent in the RBC amplitude (16.8 ± 5.2 versus 9.7 ± 2.9%; P = 0.008), chemical shift (0.43 ± 0.33 versus 0.083 ± 0.05 ppm; P < 0.001), and phase (7.7 ± 5.6 versus 1.4 ± 0.8°; P < 0.001). Dynamic 129Xe spectroscopy is a simple and sensitive tool that probes the temporal variability of gas exchange and may prove useful in discerning the underlying causes of its impairment.
Keywords:129Xe spectroscopy  dynamic spectroscopy  hyperpolarized 129Xe  hyperpolarized gas imaging  idiopathic pulmonary fibrosis  IPF  lung  spectroscopy quantitation
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号