首页 | 本学科首页   官方微博 | 高级检索  
检索        

放置MCu功能性IUD24个月临床效果观察
引用本文:梁持正.放置MCu功能性IUD24个月临床效果观察[J].中国计划生育学杂志,2005,13(2):109-111.
作者姓名:梁持正
作者单位:广东省茂名市计划生育服务中心
摘    要:目的 :观察新型MCu功能性IUD临床效果。方法 :选择放置MCu功能性IUD者 2 0 0例 ,临床观察使用 2 4个月的妊娠率、脱落率、因症取出率及续用率 ,并与TCu380A组、TCu2 2 0C组 (各 2 0 0例 )进行比较。结果 :3种IUD累计 2 4个月妊娠率每百妇女分别为 0 .5、2 .5、4 .0 ,MCu功能性IUD妊娠率低于TCu2 2 0CIUD ,差别有显著性统计学意义 (P <0 .0 5 ) ,与TCu380AIUD比较 ,差别无统计学意义 (P >0 .0 5 ) ;脱落率每百妇女分别为 1.0、7.5、7.0 ,MCu功能性IUD明显低于其它两种IUD ;因症取出率每百妇女分别为 3.0、6 .0、6 .6 ,3组间差别无统计学意义 (P >0 .0 5 ) ;续用率每百妇女分别为 95 .4、83.9、82 .3,MCu功能性IUD明显高于其它两种 ,有显著性差异 (P <0 .0 1)。结论 :MCu功能性IUD避孕效果好 ,值得推广

关 键 词:MCu功能性IUD  临床效果  续用率
修稿时间:2004年9月29日

The Observation on the Two - year's Clinical Effect of 200 Cases with Mcu Functional IUD Inserted
Liang Chizheng. Family Planning Service Station of Maoming,Guangdong.The Observation on the Two - year''''s Clinical Effect of 200 Cases with Mcu Functional IUD Inserted[J].Chinese Journal of Family Planning,2005,13(2):109-111.
Authors:Liang Chizheng Family Planning Service Station of Maoming  Guangdong
Institution:Liang Chizheng. Family Planning Service Station of Maoming,Guangdong 525000
Abstract:Objective: To observe the clinical effect of the new MCu Functional IUD. Methods :200 cases with the MCu Functional IUD were in the observing group and 200 cases with the TCu380A IUD, 200 cases with the TCu220C IUD were in the other two control groups respectively. The observation duration was two years. Results:The 24 months' accumulative pregnancy rates (per hundred women) for three varieties of IUD were as follows: 0.5, 2.5, and 4.0. And the pregnancy rate in observing group was lower than that in other two control groups, in which there was significant difference between the observing group and TCu220C IUD group (P<0.05) and no significant difference between the observing group and the TCu380A IUD group (P>0.05). The expulsion rates (per hundred women) for the three groups were as follows: 1.0, 7.5 and 7.0, where the MCu Functional IUD group was significantly lower than other two groups (P<0.01). The take off rates due to disease (per hundred women) were as follows: 3.0, 6.0 and 6.6, and there was no significant difference in three groups (P>0.05). The continuation rates for the three varieties of IUD (per hundred women) were as follows: 95.4, 83.9 and 82.3, where MCu Functional IUD group was significantly higher than other two groups (P<0.01). Conclusion:The MCu Functional IUD has a good contraceptive effect, and it should be widely used.
Keywords:MCu Functional IUD  Clinical effect  Continuation rate
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏