首页 | 本学科首页   官方微博 | 高级检索  
检索        


The effect of oral appliances that advanced the mandible forward and limited mouth opening in patients with obstructive sleep apnea: A systematic review and meta‐analysis of randomised controlled trials
Authors:K Okuno  K Sato  T Arisaka  K Hosohama  M Gotoh  H Taga  Y Sasao  S Hamada
Institution:1. Division for Oral and Facial Disorders, Osaka University Dental Hospital, , Osaka, Japan;2. Oral Cancer Center, Tokyo Dental College, , Chiba, Japan;3. Department of Oral Medicine, Oral and Maxillofacial Surgery, Tokyo Dental College, , Chiba, Japan;4. Second Department of Oral and Maxillofacial Surgery, Osaka Dental University, , Osaka, Japan;5. Dentistry and Oral Surgery, JR Tokyo General Hospital, , Tokyo, Japan;6. Center for Oral Functional Disorders, Sasao Dental Clinic, , Yamaguchi, Japan;7. Department of Oral and Maxillofacial Surgery, Kinki University Faculty of Medicine, , Osaka, Japan
Abstract:Oral appliances (OAs) have demonstrated efficacy in treating obstructive sleep apnea (OSA), but many different OA devices are available. The Japanese Academy of Dental Sleep Medicine supported the use of OAs that advanced the mandible forward and limited mouth opening and suggested an evaluation of their effects in comparison with untreated or CPAP. A systematic search was undertaken in 16 April 2012. The outcome measures of interest were as follows: Apnea Hypopnea Index (AHI), lowest SpO2, arousal index, Epworth Sleepiness Scale (ESS), the SF‐36 Health Survey. We performed this meta‐analysis using the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) system. Five studies remained eligible after applying the exclusion criteria. Comparing OA and control appliance, OA significantly reduced the weighted mean difference (WMD) in both AHI and the arousal index (favouring OA, AHI: ?7·05 events h?1; 95% CI, ?12·07 to ?2·03; P = 0·006, arousal index: ?6·95 events h?1; 95% CI, ?11·75 to ?2·15; P = 0·005). OAs were significantly less effective at reducing the WMD in AHI and improving lowest SpO2 and SF‐36 than CPAP, (favouring OA, AHI: 6·11 events h?1; 95% CI, 3·24 to 8·98; P = 0·0001, lowest SpO2: ?2·52%; 95% CI, ?4·81 to ?0·23; P = 0·03, SF‐36: ?1·80; 95% CI, ?3·17 to ?042; P = 0·01). Apnea Hypopnea Index and arousal index were significantly improved by OA relative to the untreated disease. Apnea Hypopnea Index, lowest SpO2 and SF‐36 were significantly better with CPAP than with OA. The results of this study suggested that OAs improve OSA compared with untreated. CPAP appears to be more effective in improving OSA than OAs.
Keywords:obstructive sleep apnea  oral appliance  continuous positive airway pressure  Grading of Recommendations Assessment Development and Evaluation  systematic review  randomised controlledtrials
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号