首页 | 本学科首页   官方微博 | 高级检索  
检索        


Safety and efficacy in parous women of a 52-mg levonorgestrel-medicated intrauterine device: a 7-year randomized comparative study with the TCu380A
Institution:1. UNDP/UNFPA/WHO/World Bank Special Programme of Research, Development and Research Training in Human Reproduction, Geneva, Switzerland;2. Medical Statistics Department, London School of Hygiene and Tropical Medicine, London, UK;3. Department of Reproductive Health and Research, World Health Organization, Geneva, Switzerland;4. Instituto Chileno de Medicina Reproductiva (ICMER), Santiago, Chile
Abstract:ObjectivesTo compare rates of unintended pregnancy, method continuation and reasons for removal among women using the 52-mg levonorgestrel (daily release 20 microg) levonorgestrel IUD (LNG-IUD) or the copper T 380 A (TCu380A) intrauterine device.Study designThis was an open-label 7-year randomized controlled trial in 20 centres, 11 of which in China. Data on 1884 women with interval insertion of the LNG-IUD and 1871 of the TCu380A were analysed using life tables with 30-day intervals and Cox proportional hazards models.ResultsThe cumulative 7-year pregnancy rate of the LNG-IUD was 0.5 (standard error 0.2) per 100, significantly lower than 2.5 (0.4) per 100 of the TCu380A, cumulative method discontinuation rates at 7 years were 70.6 (1.2) and 40.8 (1.3) per 100, respectively. Dominant reasons for discontinuing the LNG-IUD were amenorrhea (26.1 1.3] per 100) and reduced bleeding (12.5 1.1] per 100), particularly in Chinese women and, for the TCu380A, increased bleeding (9.9 0.9] per 100), especially among non-Chinese women. Removal rates for pain were similar for the two intrauterine devices (IUDs). Cumulative rates of removal for symptoms compatible with hormonal side effects were 5.7 (0.7) and 0.4 (0.2) per 100 for the LNG-IUD and TCu380A, respectively, and cumulative losses to follow-up at 7 years were 26.0 (1.4) and 36.9 (1.3) per 100, respectively.ConclusionThe LNG-IUD and the TCu380A have very high contraceptive efficacy, with the LNG-IUD significantly higher than the TCu380A. Overall rates of IUD removals were higher among LNG-IUD users than TCu380A users. Removals for amenorrhea appeared culturally associated.ImplicationsThe 52-mg LNG-IUD and the TCu380A have very high contraceptive efficacy through 7 years. As an IUD, the unique side effects of the LNG-IUD are reduced bleeding, amenorrhea and symptoms compatible with hormonal contraceptives.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号