首页 | 本学科首页   官方微博 | 高级检索  
检索        

智能化血管跟踪MRA在胰肾联合移植中的应用
引用本文:胡军武,朱文珍,夏黎明.智能化血管跟踪MRA在胰肾联合移植中的应用[J].放射学实践,2003,18(11):838-839.
作者姓名:胡军武  朱文珍  夏黎明
作者单位:430030,武汉,华中科技大学同济医学院附属同济医院放射科
摘    要:目的:探讨智能化血管跟踪MRA在胰肾联合移植(SPKT)中的应用。方法:搜集我院SPKT病例5例,采用GE1.5TMR扫描机,先行常规扫描,再行MRCP和MRU检查。在此基础上行Smart Prep MRA成像。所有智能化血管跟踪MRA的源影像均采用IVI软件包进行分析处理。结果:5例SPKT的智能化血管跟踪MRA的腹主动脉远端、髂内外动脉、主要移植动脉及其1~2级分支均清晰显示,其中3例患者血管异常被DSA证实。1例胰腺急性排斥反应者显示胰腺分支血管闭塞,另1例显示脾动脉的动脉瘤形成及血管连接处和胰十二指肠下动脉的近端狭窄。第3例为急性肾脏排斥反应伴肾梗死者显示肾动脉的近端及远端血管闭塞。结论:智能化血管跟踪MRA能显著提高动脉的信噪比,减少流动伪影,进而提高MRA的图像质量。

关 键 词:智能化血管跟踪MRA  胰肾联合移植  磁共振血管造影术  伪影  急性排斥反应
文章编号:1000-0313(2003)11-0838-03
修稿时间:2003年6月10日

Application of smart prep MRA in simultaneous pancreas kidney transplantation
HU Jun wu,ZHU Wen zhen,XIA Li ming.Application of smart prep MRA in simultaneous pancreas kidney transplantation[J].Radiologic Practice,2003,18(11):838-839.
Authors:HU Jun wu  ZHU Wen zhen  XIA Li ming
Institution:HU Jun wu,ZHU Wen zhen,XIA Li ming.Department of Radiology,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430022,P.R.China
Abstract:Objective:To investigate the application of Smart Prep MRA in simultaneous pancreas kidney transplantation (SPKT).Methods:5 cases with SPKT were collected from Jan,2001 to June,2002.All cases underwent Smart Prep MRA based on MRCP and MRU following conventional MR examination.All source images of Smart Prep MRA were handled with IVI software package.Results:Distal end of the abdominal aorta,internal and external iliac arteries,major transplanted arteries and their first and second level branches all were well demonstrated.Among them,3 cases with abnormality of blood vessels shown by Smart Prep MRA were confirmed by DSA.MRA documented occlusion of vascular branches of pancreas in 1 case with acute rejection of pancreas transplantation,and aneurysm of splenic artery and stenoses of blood vessels anastomosis and proximal end of inferior pancreaticoduodenal artery in another one,as well as the occlusion of the distal end and proximal end of renal arteries due to acute rejection of kidney and resultant renal infarction in the third case.Conclusion:Smart Prep MRA can increase significantly the S/N ratio of the avteries,decrease flowing artifacts and improve the image qualities of MRA.
Keywords:Smart Prep MRA  Simultaneous pancreas kidney transplantation  Magnetic resonance angiography
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《放射学实践》浏览原始摘要信息
点击此处可从《放射学实践》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号