首页 | 本学科首页   官方微博 | 高级检索  
检索        


Influence of temperature, filter wettability, and timing of filtration on the removal of WBCs from RBC concentrates
Authors:van der Meer P F  Pietersz R N  Reesink H W
Institution:Blood Bank of North Holland, Amsterdam, the Netherlands. bnhams@hetnt.nl
Abstract:BACKGROUND: The efficacy of the removal of WBCs from buffy coat-reduced RBC concentrates by filtration is determined by many variables. The aim of this study was to investigate the influence of the filtration temperature, the wettability of the filter material, and the timing of the filtration after collection. STUDY DESIGN AND METHODS: The investigation used commercially available filters: 3 dry "online" filters (Cellselect FR, Fresenius Hemocare; BioR-01-max, Fresenius; Leucoflex LCG1, MacoPharma) and one wet "inline" filter (Leucoflex LCR4, MacoPharma) that contained saline-adenine-glucose-mannitol additive solution for RBCs and differed from the online version only in wettability. After buffy coat removal and suspension in saline-adenine-glucose-mannitol, filtrations were performed immediately at room temperature (RT) and after 2 hours' storage of the RBC concentrates at 4 degrees C, while the Leucoflex LCR4 was also tested after 24 hours' storage of the RBC concentrates at 4 degrees C. Sets of 12 pooled experiments were performed to prevent donor-dependent differences. RESULTS: The Cellselect FR gave significantly better WBC removal from RBC concentrates at 4 degrees C than at RT, with residual WBCs of 1.44 +/- 0.58 x 10(6) and 2.78 +/- 1.23 x 10(6), respectively (p<0.001). The BioR-01-max gave no significant difference: 0.62 +/- 0.27 x 10(6) WBCs (at 4 degrees C) versus 0.61 +/- 0.25 x 10(6) WBCs (at RT). Filtration with the Leucoflex LCG1 resulted in 0.06 +/- 0.03 x 10(6) and 0.07 +/- 0.07 x 10(6) WBCs at 4 degrees C and RT, respectively, which is not a significant difference. The Leucoflex LCR4, however, gave 2.08 +/- 0.84 x 10(6) WBCs at RT, 0.52 +/- 0.44 x 10(6) WBCs at 4 degrees C after 2 hours' cooling, and 0.05 +/- 0.10 x 10(6) WBCs at 4 degrees C after 24 hours' cooling (all p<0.001). CONCLUSION: Temperature, filter wettability, and timing of filtration after collection influence the efficacy of a filter for RBC concentrates. These variables need to be established, validated, and controlled before a filter can be selected for routine use.
Keywords:BC = buffy coat  RT = room temperature  SAG-M = saline-adenine-glucose-mannitol
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号