首页 | 本学科首页   官方微博 | 高级检索  
检索        


Relationship Between Computed Tomographic Image Analysis and Histomorphometry for Microarchitectural Characterization of Human Calcaneus
Authors:Email author" target="_blank">B?CortetEmail author  D?Chappard  N?Boutry  P?Dubois  A?Cotten  X?Marchandise
Institution:(1) Department of Rheumatology, University-Hospital of Lille, 59037 Lille, CEDEX, France;(2) Unité de Recherche de lrsquoappareil locomoteur, CH & U Lille, University of Lille, 59037 Lille, CEDEX, France;(3) Department of Histology and Embryology, University of Angers, 49045 Angers, CEDEX, France;(4) Department of Radiology, University of Angers, 49045 Angers, CEDEX, France;(5) Department of Biophysics, University-Hospital of Lille, 59037 Lille, CEDEX, France
Abstract:The present study aimed to characterize the relationships between several variables reflecting bone microarchitecture assessed by both computed tomographic (CT) image analysis and histomorphometry (conventional CT system) at the calcaneus. A total of 24 cadaveric specimens were studied. The mean age at death was 78 ± 10 years (range, 53–93 years). A total of 15 sagittal sections (1 mm in width and spaced 2 mm apart) were selected for CT analysis; 6 undecalcified sections (7 mgrm) were analyzed for histomorphometry. The histomorphometric analysis was performed on a Leica Quantimet Q570 image analyzer. Features measured by both methods were: bone volume/tissue volume (BV/TV), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), trabecular number (Tb.N), interconnectivity index (ICI), number of nodes (N Nd), number of terminus (N Tm), node-to-node strut count (NNS), node-to-terminus strut count (NTS), terminus-to-terminus strut count (TTS), marrow space star volume (SV), Euler number (EN), and fractal dimension (FD). The coefficient of correlationsrsquo values (simple linear regression) between histomorphometry and CT image analysis varied according to the parameters selected. R values were high for BV/TV, Tb.N, and Tb.Sp (range, 0.69–0.90; P < 0.01). R values were less significant for some variables also obtained from the binary image: SV (0.5, P < 0.05) and EN (0.43, P < 0.05). Finally R values were also significant for (two) variables obtained from skeletonized images, i.e., N Nd (0.4, P < 0.05) and N Tm (0.61, P < 0.01). Other correlations were not statistically significant. Moreover, for some variables the relationships between the two methods (CT analysis and histomorphometry) seemed best-described by using nonlinear models. For example, a logarithmic model was more appropriate for SV (r = 0.71, P < 0.01), N Nd (r = 0.52, P < 0.01). Finally the relationship between apparent (App) N Tm and N Tm was most satisfying when using an exponential model (r = 0.64, P < 0.01). In conclusion, trabecular bone structure measures determined on CT images show highly significant correlations with those determined using histomorphometry. The level of correlation varies according to the type of method used for characterizing bone structure, however, and the strongest correlations were found for the most basic features (Parfittrsquos parameters). Finally, for some variables, nonlinear models seem more appropriate.
Keywords:Computed tomography  Histomorphometry  Bone microarchitecture  Bone texture analysis  Bone mineral density
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号