首页 | 本学科首页   官方微博 | 高级检索  
     


Semiautomatic Quantification of Left Ventricular Function by Two‐Dimensional Feature Tracking Imaging Echocardiography. A Comparison Study with Cardiac Magnetic Resonance Imaging
Authors:Gianluca Di Bella M.D.   Ph.D.  Concetta Zito M.D.  Michele Gaeta M.D.  Maurizio Cusmà Piccione M.D.  Fabio Minutoli M.D.  Rocco Donato M.D.  Antonino Recupero M.D.  Antonio Madaffari M.D.  Sebastiano Coglitore M.D.  Scipione Carerj M.D.
Affiliation:1. Clinical and Experimental Department of Medicine and Pharmacology, University of Messina, Messina, Italy;2. Department of Radiological Science, University of Messina, Messina, Italy
Abstract:Objective: To evaluate the accuracy of a semiautomatic quantification of left ventricular (LV) volumes and ejection fraction (EF) using two‐dimensional (2D) feature tracking imaging (FTI). Methods: Thirty‐four consecutive subjects (11 patients with dilated cardiomyopathy, 13 with hypertrophic cardiomyopathy, and 10 subjects with no cardiac disease) underwent, on the same day, trans‐thoracic echocardiography (TTE) examination, FTI, and cardiac magnetic resonance imaging (MRI), as gold standard, in order to quantify LV volumes and EF. The echocardiographic quantification of LV volumes and EF was determined from four‐ and two‐chamber views using both standard TTE Biplane Simpson's method and a semiautomatic border detection based on FTI. Furthermore, the time for data analysis for each method was measured. Results: The time required for semiautomatic analysis of volumes and EF was significantly lower (P < 0.0001) by FTI (71 seconds) in comparison with standard biplane Simpson's method (93 seconds). LV volumes obtained by FTI were significant underestimated (P < 0.001) in comparison with MRI. Bland‐Altman analysis of EDV and ESV using FTI and cardiac MRI showed a low level of agreement for EDV (mean difference = 40.8; SD = 39) and ESV (mean difference = 38.1; SD = 42). On the contrary, no significant difference between FTI and MRI in assessing the LVEF was found; furthermore, a very low bias (2 ± 12) by Bland‐Altman analysis was found between FTI and cardiac MRI for the quantification of EF. Conclusion: Semiautomatic quantification of LV volumes using FTI allows an accurate, rapid, easy and reliable assessment of LV EF and a rough estimation of LV volumes. (Echocardiography 2010;27:791‐797)
Keywords:transthoracic echocardiography  feature tracking imaging echocardiography  speckle tracking imaging  left ventricular volumes  ejection fraction  cardiac magnetic resonance imaging
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号