首页 | 本学科首页   官方微博 | 高级检索  
     

低场磁共振DWI技术与常规MRI扫描对超急性脑梗死的诊断灵敏度的比较
引用本文:唐令胜,刘朝晖,李红梅,陈伟棠,陈颖峰. 低场磁共振DWI技术与常规MRI扫描对超急性脑梗死的诊断灵敏度的比较[J]. 国际放射医学核医学杂志, 2016, 40(3): 187-190. DOI: 10.3760/cma.j.issn.1673-4114.2016.03.006
作者姓名:唐令胜  刘朝晖  李红梅  陈伟棠  陈颖峰
作者单位:529200, 广东省台山市人民医院医学影像科
摘    要:目的 探讨低场磁共振弥散加权成像(DWI)技术与常规MRI扫描对超急性脑梗死的诊断价值差异。 方法 选择2014年4月至2015年3月期间收治的临床疑诊为脑缺血病例78例, 分别采用低场磁共振DWI技术与常规MRI扫描技术进行检查, 评价两种检查技术对超急性脑梗死的诊断灵敏度。 结果 低场磁共振DWI诊断超急性脑梗死的灵敏度为100.00%(72/72), 而常规MRI扫描的诊断灵敏度仅为5.56%(4/72), 可见采用低场磁共振DWI技术的诊断灵敏度显著高于常规MRI扫描技术。 结论 低场磁共振DWI技术应用于超急性脑梗死的诊断中, 可有效提高其诊断灵敏度, 其效果显著优于常规MRI扫描, 值得在临床上推广使用。

关 键 词:脑梗死   磁共振成像  弥散   磁共振成像   诊断   灵敏度
收稿时间:2016-01-13

Comparison of the diagnostic sensitivity of low-field magnetic resonance diffusion weighted imaging technology and conventional MRI scanning for super acute cerebral infarction
Lingsheng Tang,Zhaohui Liu,Hongmei Li,Weitang Chen,Yingfeng Chen. Comparison of the diagnostic sensitivity of low-field magnetic resonance diffusion weighted imaging technology and conventional MRI scanning for super acute cerebral infarction[J]. International Journal of Radiation Medicine and Nuclear Medicine, 2016, 40(3): 187-190. DOI: 10.3760/cma.j.issn.1673-4114.2016.03.006
Authors:Lingsheng Tang  Zhaohui Liu  Hongmei Li  Weitang Chen  Yingfeng Chen
Affiliation:Department of Medical Imaging, Taishan People's Hospital, Taishan 529200, China
Abstract:Objective To investigate the differences in the diagnostic values of low-field magnetic resonance diffusion weighted imaging(DWI) technology and conventional MRI scanning for super acute cerebral infarction.Methods A total of 78 suspected cases of cerebral ischemia were clinically treated in Guangdong Taishan People's Hospital between April 2014 and July 2015.These cases were examined using low-field magnetic resonance DWI and conventional MRI scanning technology,which are two kinds of inspection technologies for super acute cerebral infarction diagnostic sensitivity.Results The diagnostic sensitivity of the low-field magnetic resonance DWI(100.00%,72/72) was significantly higher than that of conventional MRI(5.56%,4/72).Conclusions Low-field magnetic DWI technology can effectively improve diagnostic sensitivity in the diagnosis of super acute cerebral infarction and can produce a significantly better effect than the conventional MRI scan.Therefore,this tool is worth popularizing in clinical use.
Keywords:Brain infarction  Diffusion magnetic resonance imaging  Magnetic resonance imaging  Diagnosis  Sensitivity
本文献已被 万方数据 等数据库收录!
点击此处可从《国际放射医学核医学杂志》浏览原始摘要信息