Influence of maxillomandibular positioning in cone beam computed tomography for implant planning
Authors:M.A.P.G. Visconti  F.S. Verner  N.M.S.P. Assis  K.L. Devito
Affiliation:Faculty of Dentistry, Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil
Abstract:The aim of this study was to evaluate the influence of changes in maxillomandibular positioning during cone beam computed tomography (CBCT) imaging on the planning of dental implants. Ten skulls were marked bilaterally with metal spheres in four regions: incisors, canine, premolars, and molars. CBCT scans were obtained in seven positions: standard position (SP), displacements of 10° and 20° above and below the SP, and lateral displacements of 10° and 20° from the SP. Subsequently, bilateral measurements of the height and width of the maxilla and mandible were performed on all images. The results showed that the position with a displacement of 20° above the SP presented the greatest differences in the measurements of bone height and width. In the bilateral comparisons, the maxillary bone width showed the greatest differences, especially for the regions of the premolars and molars. It is concluded that alterations of positioning during the acquisition of CBCT images can lead to alterations in the measurements of bone height and width, which may result in errors in implant planning and cause damage to anatomical structures.
Keywords:cone beam computed tomography  dental implants  patient positioning