Semi-automated method for the determination of free fatty acids in plasma
Authors:Joyce D. Baird   M. W. Black     D. E. Faulkner
Affiliation:.Department of Medicine, University of Edinburgh, Edinburgh;.Western General Hospital, Edinburgh;.Biological Control Laboratories, Wellcome Foundation, Dartford, Kent
Abstract:A semi-automated method for the determination of free fatty acids in plasma based on Mosinger's manual method (Mosinger, 1965) is described and the results of a comparison with Dole's titrimetric method (Dole, 1956) are presented. There is almost perfect correlation between the two methods, and the automated technique is simple, reliable, and significantly more accurate and precise than the titrimetric method.