摘    要:介绍了一起220kVXLPE电缆接地线发热缺陷的处理经过,分析并找到其发热的原因,最后提出预防电缆接地系统发热的措施及处理同类缺陷的方法。

关 键 词:XLPE电缆;接地线;发热;红外测温;环流;接触电阻

the Research on the cause for the Accident of 220kV Wenping A-Wire Ground Lead Heat Generation
WANG Dao-long. the Research on the cause for the Accident of 220kV Wenping A-Wire Ground Lead Heat Generation[J]. Chinese Journal of Medical Library and Information Science, 2010, 0(2): 54-55
Authors:WANG Dao-long
Affiliation:(Guangdong Power Grid Company Foshan Power Supply Bureau Foshan, Guangdong Providence, 528000)
Abstract:The article introduces the handling process of heat generation caused by a 220 kv XLPE cable ground lead. After some analysis, we find out what caused the heat generation and finally put forward the measures to prevent the heat generation of cable grounding system and ways to deal with similar cases.