首页 | 本学科首页   官方微博 | 高级检索  
检索        


A Multicenter, Randomized, Controlled Trial Comparing Bupivacaine with Ropivacaine for Labor Analgesia
Authors:Halpern  Stephen H MD  MSc  FRCPC; Breen  Terrance W MD  FRCPC&#x;; Campbell  David C MD  MSc  FRCPC&#x;; Muir  Holly A MD  FRCPC&#x;; Kronberg  Jean MD  PhD  FRCPC; Nunn  Robert MD  FRCPC ; Fick  Gordon H PhD&#x;
Institution:Halpern, Stephen H. M.D., M.Sc., F.R.C.P.C.*; Breen, Terrance W. M.D., F.R.C.P.C.?; Campbell, David C. M.D., M.Sc., F.R.C.P.C.?; Muir, Holly A. M.D., F.R.C.P.C.?; Kronberg, Jean M.D., Ph.D., F.R.C.P.C.*; Nunn, Robert M.D., F.R.C.P.C.§; Fick, Gordon H. Ph.D.∥
Abstract:Background: A meta-analysis of studies comparing high doses of bupivacaine with ropivacaine for labor pain found a higher incidence of forceps deliveries, motor block, and poorer neonatal outcome with bupivacaine. The purpose of this study was to determine if there is a difference in these outcomes when a low concentration of patient-controlled epidural bupivacaine combined with fentanyl is compared with ropivacaine combined with fentanyl.

Methods: This was a multicenter, randomized, controlled trial, including term, nulliparous women undergoing induction of labor. For the initiation of analgesia, patients were randomized to receive either 15 ml bupivacaine, 0.1%, or 15 ml ropivacaine, 0.1%, each with 5 mu]g/ml fentanyl. Analgesia was maintained with patient-controlled analgesia with either local anesthetic, 0.08%, with 2 mu]g/ml fentanyl. The primary outcome was the incidence of operative delivery. We also examined other obstetric, neonatal, and analgesic outcomes.

Results: There was no difference in the incidence of operative delivery between the two groups (148 of 276 bupivacaine recipients vs. 135 of 279 ropivacaine recipients;P = 0.25) or any obstetric or neonatal outcome. The incidence of motor block was significantly increased in the bupivacaine group compared with the ropivacaine group at 6 h (47 of 93 vs. 29 of 93, respectively;P = 0.006) and 10 h (29 of 47 vs. 16 of 41, respectively;P = 0.03) after injection. Satisfaction with mobility was higher with ropivacaine than with bupivacaine (mean +/- SD: 76 +/- 23 vs. 72 +/- 23, respectively;P = 0.013). Satisfaction for analgesia at delivery was higher for bupivacaine than for ropivacaine (mean +/- SD: 71 +/- 25 vs. 66 +/- 26, respectively;P = 0.037).

Keywords:
点击此处可从《The Journal of the American Society of Anesthesiologists》浏览原始摘要信息
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号