摘    要:目的 建立复方红景天口服液的微生物限度检查方法。方法 按照《中华人民共和国药典》(2010年版)附录微生物限度检查法中细菌、霉菌及酵母菌数计数方法和控制菌检查方法进行验证。结果 金黄色葡萄球菌采用培养基稀释法,大肠杆菌、枯草芽孢杆菌、白念珠菌、黑曲霉采用常规法,回收率>70%;控制菌检查中,各阳性实验菌均检出,阴性对照无菌生长。结论 经验证,复方红景天口服液微生物限度采用培养基稀释法检查金黄色葡萄球菌;采用常规法检查大肠杆菌、枯草芽孢杆菌、白念珠菌、黑曲霉等。

关 键 词:复方红景天口服液  微生物限度检查  方法学验证
收稿时间:1/5/2015 12:00:00 AM
修稿时间:2015/7/15 0:00:00

Validation of microbial limit tests for compound Hongjingtian oral liquid
CHEN Yalin,FENG Xu,CHEN Hong,LUAN Jie,ZHAO Long and WANG Jiachun.Validation of microbial limit tests for compound Hongjingtian oral liquid[J].The Journal of Pharmaceutical Practice,2016,34(2):177-178.
Authors:CHEN Yalin  FENG Xu  CHEN Hong  LUAN Jie  ZHAO Long and WANG Jiachun
Institution:Naval Medical Research Institute of PLA, Shanghai 200433, China,Naval Medical Research Institute of PLA, Shanghai 200433, China,Tianjin University of Science and Technology, Tianjin 300457, China,Naval Medical Research Institute of PLA, Shanghai 200433, China,Tianjin University of Science and Technology, Tianjin 300457, China and Naval Medical Research Institute of PLA, Shanghai 200433, China
Abstract:Objective To establish a method of microbial limit tests for compound Hongjingtian oral liquid and to perform the validation of the method. Methods The validation on the microbial limit test method was conducted according to the counting method of bacteria,mycetes and yeasts and the control bacteria test method stated in the appendix of China pharmacopoeia(2010 edition). Results The recoveries were over 70% when culture diluting method was used for staphylococcus aureus and routine test method was used for Escherichia coli, Bacillus subtilis,Candida albicans and Aspergillus niger. In the test of positive control bacteria, the growth was detected, while the negative control was no growth detected. Conclusion The microbial limit test for compound Hongjingtian oral liquid is validated in this study. The amount of staphylococcus aureus can be determined using diluted culture method; while the amounts of Escherichia coli, Bacillus subtilis,Candida albicans, Aspergillus niger can be determined by conventional method.
Keywords:compound Hongjingtian oral liquid  microbial limit test  validation of the method
点击此处可从《药学实践杂志》浏览原始摘要信息
点击此处可从《药学实践杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号