Abstract: | The peak velocities of horizontal saccades were measured in patients with myasthenia gravis (MG) to determine whether they can differentiate MG from other causes of ophthalmoplegia. Eye movements were recorded with electrooculography (EOG) or infrared scleral reflection (IR) in 42 patients with MG, 26 patients with sixth cranial nerve palsy (CNP), 19 patients with chronic progressive external ophthalmoplegia (PEO) and 28 normal subjects. Despite limitation of ductions in MG, the group means of velocities of 10 deg saccades recorded with IR were similar in MG and normal subjects. With EOG, small but statistically significant decreases in mean velocities of 10, 20 and 30 deg saccades were found in MG, compared to those in normal subjects. Twenty-one to 28% of MG patients had velocities outside of the normal range (outliers). In contrast, the group means in CNP and PEO were markedly lower than those in MG and normal subjects. The frequencies of outliers were 89 to 100% in CNP and 88 to 100% in PEO. Measurement of saccadic velocities can be helpful in differentiating MG from other causes of ophthalmoplegia. |