首页 | 本学科首页   官方微博 | 高级检索  
     


Local differences in the trabecular bone structure of the proximal femur depicted with high-spatial-resolution MR imaging and multisection CT
Authors:Issever Ahi Sema  Vieth Volker  Lotter Albrecht  Meier Norbert  Laib Andres  Newitt David  Majumdar Sharmila  Link Thomas M
Affiliation:

aMagnetic Resonance Science Center, Department of Radiology, University of California, San Francisco, USA

bDepartment of Clinical Radiology, University of Münster, Germany

cScanco Medical, Bassersdorf, Switzerland

dDepartment of Radiology, Klinikum Rechts der Isar, Technische Universität München, Ismaninger Strasse 22, 81675 Munich, Germany

Abstract:RATIONALE AND OBJECTIVES: The authors performed this study to investigate structural variations in the trabecular bone of the proximal femur at high-resolution magnetic resonance (MR) imaging and high-resolution multisection computed tomography (CT). MATERIALS AND METHODS: Bone mineral density (BMD) was measured in 36 proximal human femur specimens by using dual x-ray absorptiometry. High-resolution MR imaging was performed at 1.5 T with an in-plane spatial resolution of 0.195 x 0.195 mm and a section thickness of 0.3 and 0.9 mm. Multisection CT was performed with an ultra-high-resolution protocol; images were obtained with an in-plane spatial resolution of 0.25 mm and a section thickness of 1 mm. In a subset of these specimens, micro CT was performed with an isotropic spatial resolution of 30 microm. Identical regions of interest (ROIs) were used to analyze images obtained with MR imaging, multisection CT, and micro CT. Trabecular bone structural parameters were obtained, and the parameters from the individual imaging modalities and BMD were correlated. RESULTS: Significant differences concerning the trabecular microarchitecture between the individual ROIs were demonstrated with multisection CT and MR imaging. A number of the correlations between structural parameters derived with multisection CT, MR imaging, micro CT, and BMD measurements were significant. For MR imaging, threshold technique and section thickness had an effect on structural parameters. CONCLUSION: Structural parameters obtained in the proximal femur with multisection CT and high-resolution MR imaging show regional differences. These techniques may be useful for depicting the trabecular architecture in the diagnosis of osteoporosis.
Keywords:Computed tomography (CT), high-resolution   femur, CT   femur, MR   magnetic resonance (MR), high resolution   osteoporosis
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号