首页 | 本学科首页   官方微博 | 高级检索  
检索        

骶丛及邻近坐骨神经MR成像技术优化探讨
引用本文:刘丽芬,杜湘珂,陈雷.骶丛及邻近坐骨神经MR成像技术优化探讨[J].中国医学影像技术,2005,21(5):806-808.
作者姓名:刘丽芬  杜湘珂  陈雷
作者单位:北京大学人民医院放射科,北京,100044
摘    要:目的探讨骶丛及邻近坐骨神经的MR优化成像方法及其临床应用价值.方法对20例健康志愿者及7例坐骨神经继发病变患者行骶丛及邻近坐骨神经的二维自旋回波(2D-SE)序列 T1WI和快速自旋回波抑脂(FSE F/S)序列T2WI的斜矢状位成像,轴位三维快速平衡稳态进动(3D-FIESTA)序列成像并多平面重建,其中10例志愿者加做单侧斜位3D-FIESTA序列成像, 7例患者平扫后行Gd-DTPA增强扫描.对比正常组2D-SE T1WI斜矢状位与轴位3D-FIESTA序列多平面重建对骶1神经(S1)及邻近坐骨神经的显示率.运用四等级评分标准方法评价两种采集方式的3D-FIESTA多平面重建对骶丛各支神经的显示程度并进行统计学分析.结果正常志愿者中2D-SE 序列与3D-FIESTA序列对S1及邻近坐骨神经显示率分别为70%和95%(P<0.01).轴位与斜位3D-FIESTA对腰骶干(LST)及S1的显示能力有显著性差异(二者分别为P<0.01,P<0.05),对S2及S3的显示程度无显著性差异.病例组通过多平面重建可明确骶丛各支神经及邻近坐骨神经受累情况.结论 3D-FIESTA序列通过重建可分别显示骶丛各支神经,对S1及邻近坐骨神经的显示率明显高于2D-SE序列,单侧斜位采集优于轴位采集.

关 键 词:骶丛  坐骨神经  磁共振成像
文章编号:1003-3289(2005)05-0806-03
收稿时间:2004/12/5 0:00:00
修稿时间:2004年12月5日

MR optimal technique for imaging sacral plexus and adjacent sciatic nerve
LIU Li-fen,DU Xiang-ke and CHEN Lei.MR optimal technique for imaging sacral plexus and adjacent sciatic nerve[J].Chinese Journal of Medical Imaging Technology,2005,21(5):806-808.
Authors:LIU Li-fen  DU Xiang-ke and CHEN Lei
Institution:Department of Radiology, People's Hospital of Peking University, Beijing 100044, China;Department of Radiology, People's Hospital of Peking University, Beijing 100044, China;Department of Radiology, People's Hospital of Peking University, Beijing 100044, China
Abstract:Objective To study the MR optimal technique for demonstrating sacral plexus (SP) and adjacent sciatic nerves (SN) as well as its clinical value. Methods The SPs and adjacent SNs of 20 volunteers and 7 patients were imaged by GE-Signa CV/I 1.5 T MR scanner with the sequences of 2-dimension spin echo (2D-SE) T1WI, fast spin echo fat saturation (FSE F/S )T2WI oblique sagittal imaging,axial 3-dimension fast imaging employing steady state acquisition (3D-FIESTA), and additional oblique 3D-FIESTA in 10 of the 20 volunteers. The displaying rate of sacral(S_1) nerves and adjacent SNs were compared between 2D-SE T1WI and reconstructive images of axial 3D-FIESTA. The displaying degree of SPs and adjacent SNs on reconstructive images of axial and oblique 3D-FIESTA was graded, and average scores were analyzed with Wilcoxon signed rank tests. Results The displaying rates of S_1 and adjacent SN were significantly different between 2D-SE and 3D-FIESTA ( P <0.01). Oblique 3D-FIESTA was superior to axial 3D-FIESTA for demonstrating LST and S_1, but there was no significant difference in S_2 and S_3. Sacral nerves of the 7 patients were invaded and/or displaced. Conclusion Reconstructive images of 3D-FIESTA is better than 2D-SE for demonstrating of S_1 and adjacent SN, and can display every sacral nerve. Oblique acquisition is better than axial one.
Keywords:Sacral plexus  Sciatic nerve  Magnetic resonance imaging
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号