首页 | 本学科首页   官方微博 | 高级检索  
检索        

多尺寸人工全膝关节系统的临床应用分析及随访结果
引用本文:高升焘,万连平,张鹏,杜建春,孙伟,林均馨,刘泽淼,孔杰.多尺寸人工全膝关节系统的临床应用分析及随访结果[J].中华关节外科杂志(电子版),2013(6):25-28.
作者姓名:高升焘  万连平  张鹏  杜建春  孙伟  林均馨  刘泽淼  孔杰
作者单位:山东大学齐鲁医院青岛关节外科,青岛266021
摘    要:目的 探讨应用多尺寸膝关节假体系统的临床应用优势及早期随访结果.方法 回顾性分析自2010年12月至2012年12月78例应用Vanguard膝关节系统进行人工全膝表面关节置换患者.术中记录应用股骨假体型号,术后定期门诊随访,拍摄X线片,应用KSS评分和WOMAC评分评估手术效果.结果 78例患者平均随访15.8个月.术前KSS评分(34.68±8.07)分,WOMAC评分(62.40±3.74)分,术后末次随访KSS评分(84.99±3.64)分,WOMAC评分(25.86±3.31)分.术前患者膝关节平均屈曲度(95.83°±13.83°),术后末次随访时患者膝关节平均屈曲度(122.63°±9.93°).患者术后膝关节功能明显改善,评分具有统计学差异(P〈0.01).常用股骨假体型号在55~70 mm之间,并且70%以上集中在60~65 mm.结论 Vanguard膝关节假体能满足不同个体的需求,适应性强,有利于伸屈间隙的平衡,假体覆盖好,早期随访临床效果满意.

关 键 词:关节成形术  置换    随访研究  治疗结果

Clinical application analysis and follow-up results of multi-size total knee prosthesis system
GAO Sheng-tao,WAN Lian-ping,ZHANG Peng,DU Jian-chun,SUN Wei,LIN Jun-xin,LIU Ze-miao,KONG Jie.Clinical application analysis and follow-up results of multi-size total knee prosthesis system[J].Chinese Journal of Joint Surgery(Electronic Version),2013(6):25-28.
Authors:GAO Sheng-tao  WAN Lian-ping  ZHANG Peng  DU Jian-chun  SUN Wei  LIN Jun-xin  LIU Ze-miao  KONG Jie
Institution:. (Department of Joint Surgery, Qilu Hospital of Shandong University, Qingdao 266021, China)
Abstract:Objective To discuss the benefits of multi-size totle knee prosthesis system and the early follow-up results. Methods 78 patients underwent total knee arthroplasty (TKA) with Vanguard complete knee system from December 2010 to December 2012. The femoral prosthesis size was recorded. HSS and WOMAC were used to evaluate the overall outcomes in the follow-up. Results 78 patients were followed up for 15.8 months in average. The preoperative KSS score was ( 34. 68 ± 8.07 ) , and the WOMAC score was (62.40 ± 3.74). At the last follow-up, the postoperative KSS score was ( 84.99 ± 3.64) and the WOMAC score was (25.86 ± 3.31 ). The average knee flexion degree was (95.83° ± 13.83°) preoperation. At the last follow-up, the average knee flexion degree was (122. 63° ± 9.93°). The postoperative knee function improved significantly. The scores had statistically significant difference. The common femoral prosthesis size was 55 - 70 mm, and the size of more than 70% prostheses was between 60 -65 mm. Conclusion The Vanguard complete knee system can meet the needs of different individuals, and it is good for the balance of the flexion and extension gap. The early follow-up clinical outcomes are satisfactory.
Keywords:Arthroplasty  replacement  knee  Follow-up studies  Treatment outcome
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号