作者单位:刘跟生 (山东电力研究院化学与环境工程研究所,山东济南,250002) ; 江红 (山东电力研究院化学与环境工程研究所,山东济南,250002) ; 沈竞为 (山东电力研究院化学与环境工程研究所,山东济南,250002) ; 张永 (山东电力研究院化学与环境工程研究所,山东济南,250002) ;
摘    要:目的]分析不同类型500kV变电站运行人员接触工频电场及工频磁场的强度。方法]利用PMM 8053A/EHP-50C电磁场强度测试仪检测作业场所工频电场及工频磁场强度,将检测结果与相关标准进行比较。结果]本次研究共检测148个作业点的工频电场及工频磁场强度,其中44个作业点的工频电场强度大于5kV/m,其中1个作业点工频电场强度达10220V/m;所有作业点中工频磁场强度最大值为35.11μT;采用时间加权法,计算得出不同类型500kV变电站运行人员每周56h接触工频电场强度值分别为738V/m、481V/m和144V/m。结论]不同类型500kV变电站运行人员接触工频电场的强度值均符合小于国家职业卫生标准限值的要求,接触工频磁场强度值也均符合小于国家电力行业标准限值的要求。

关 键 词:500kV变电站  工频电场  工频磁场

Analysis on Power Frequency Electric and Magnetic Field Intensity at Workplace of 500 kV Substations
LIU Gen-sheng,JIANG Hong,SHEN Jing-wei,ZHANG Yong.Analysis on Power Frequency Electric and Magnetic Field Intensity at Workplace of 500 kV Substations[J].Journal of Labour Medicine,2011,28(11):661-663.
Authors:LIU Gen-sheng  JIANG Hong  SHEN Jing-wei  ZHANG Yong
Institution:(Institute of Chemical and Environmental Engineering, Shandong Electric Power Research Institute, Jinan, Shandong 250002, China)
Abstract:Objective] To analyze the power frequency electric and magnetic field intensity exposed to the operators at the workplace of 500kV substations.Methods] The levels of power frequency electric and magnetic fields were measured with PMM 8053A/PMM EHP-50C.The results were compared with relevant standards.Results] The power frequency electric and magnetic field intensity of 148 work sites were measured.Among these results,44 were greater than 5kV/m in respect of power frequency electric field intensity,and 1 reached 10220V/m.The maximum power frequency magnetic field intensity was 35.11μT.The calculated levels of power frequency electric field exposure in terms of time-weighted strength per week(56h) were 738V/m,481V/m and 144V/m in various types of 550kV substations.Conclusion] In these 500kV substations,the operators’exposure to power frequency electric field meet the national occupational health standards,and their exposure to power frequency magnetic field meet the national power industry requirements.
Keywords:500 kV substation  power frequency electric field  power frequency magnetic field