首页 | 本学科首页   官方微博 | 高级检索  
     

多层螺旋CT对肾癌的灌注研究
引用本文:王芳,王青,李笃民. 多层螺旋CT对肾癌的灌注研究[J]. 山东大学学报(医学版), 2006, 44(7): 726-728
作者姓名:王芳  王青  李笃民
作者单位:山东大学齐鲁医院影像中心,山东 济南 250012
摘    要:目的:探讨多层螺旋CT对肾癌的灌注特点。方法: 对25例经手术病理证实为肾癌患者(肿瘤组)和22例健康志愿者(正常对照组)进行多层螺旋CT灌注扫描,所得数据送入Advanced Workstation 4.2工作站,应用perfusion3软件分别测量肿瘤组与对照组肾皮质、髓质的灌注参数:血流量(BF)、血容量(BV)、对比剂平均通过时间(MTT)、毛细血管表面通透系数(PS)、强化峰值(PV)和峰值时间(TTP)。结果:肿瘤组BF、BV、MTT和PS与对照组肾皮质、髓质的相应灌注参数间差异有统计学意义(P<0.05)。肿瘤组TTP与对照组肾皮质TTP差异无显著性,而PV差异有显著性。肿瘤组BF低于对照组肾皮质、高于肾髓质;BV高于对照组肾皮质及肾髓质;MTT与PS高于对照组肾皮质、低于肾髓质;PV低于对照组肾皮质;TTP高于对照组肾皮质。结论:肾癌CT灌注参数BF、BV、MTT、PS、PV和TTP不同于正常肾皮、髓质,有其特点。

关 键 词:体层摄影术,X线计算机  肾肿瘤  灌注,局部
文章编号:1671-7554(2006)07-0726-03
收稿时间:2005-06-08
修稿时间:2005-06-08

Multi-slice spiral computed tomography perfusion of the renal cancer
WANG Fang,WANG Qing,LI Du-min. Multi-slice spiral computed tomography perfusion of the renal cancer[J]. Journal of Shandong University:Health Sciences, 2006, 44(7): 726-728
Authors:WANG Fang  WANG Qing  LI Du-min
Affiliation:Imaging Center, Qilu Hospital of Shandong University, Jinan 250012, Shandong, China
Abstract:Objective: To study the characteristics of multi-slice spiral computed tomography perfusion of the renal cancer.Methods: Multi-slice spiral computed tomography perfusion was performed on 25 patients with renal cancer and 22 volunteers as control.All data were sent to advanced workstation 4.2,and the perfusion parameters,such as blood flow(BF),blood volume(BV),mean transit time(MTT),capillary permeability surface(CPS),peak value(PV) and time to peak(TTP) of the tumor and the renal cortex or the medulla were obtained by Perfusion 3 software.Results: BF,BV,MTT,PS and PV was statistically different between the cancer and the renal cortex or medulla of the control group(P<0.05),whereas TTP was not.BF was lower in cancer group than that in normal renal cortex,but was higher than that of medulla;BV was higher in cancer group than that in normal renal cortex or medulla;Both MTT and PS were longer in tumor group than those in normal renal cortex,but were shorter than those in medulla;PV was lower in tumor group than that in normal renal cortex;TTP was longer than that of normal renal cortex.Conclusion: The characteristics of CT perfusion imaging of the renal cancer are different from the normal kidney cortex or medulla in BV,BF,MTT and PS.
Keywords:Tomography, X-my computed   Kidney neoplasms   Perfusion, regional
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《山东大学学报(医学版)》浏览原始摘要信息
点击此处可从《山东大学学报(医学版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号