首页 | 本学科首页   官方微博 | 高级检索  
     


Manual and automated polyp measurement comparison of CT colonography with optical colonoscopy
Authors:Jeong Jun Yong  Kim Min Ju  Kim Sam Soo
Affiliation:Department of Radiology, Kangwon National University College of Medicine, 192-1 Hyoja 2-dong, Chuncheon, Kangwon-do 200-701, Korea.
Abstract:RATIONALE AND OBJECTIVES: The purpose of this study was to assess (1) the agreement of two-dimensional (2D) and three-dimensional (3D) manual and automated polyp linear diameter measurements at CT colonography (CTC), with optical colonoscopic equivalents and (2) intraobserver and interobserver agreement of the CTC measurements. MATERIALS AND METHODS: Using the same CTC system, two radiologists independently measured the maximum linear diameter of 44 polyps (reference size 3-15 mm) matched on CTC and optical colonoscopy: manual 2D optimized multiplanar reformatted planes with standard window settings (level 1500 HU, width -200 HU), manual 3D measurement with software calipers and automated 3D measurement with software. After 2 weeks, polyps were measured again. Compatibility of CTC measurement with that of optical colonoscopy and measurement reproducibility was assessed statistically. RESULTS: In the manual measurement, 44 polyps were analyzed and 41 in automated measurement; three polyps could not be extracted. Although the measurement difference was noted for automated, manual 3D, and manual 2D measurements, statistically supported agreement with optical colonoscopic measurement was noted only with manual 2D measurement for both observers. However, 95% limits of agreement were wide for all the measurement methods. When categorized according to the optical colonoscopic measurement, manual 2D, 3D, and automated measurements showed "good" agreement. Although intraobserver and interobserver agreement was good with manual measurement, intraobserver and interobserver agreement was excellent with automated measurement. CONCLUSION: Manual 2D measurements demonstrated trends of better approximation to optical colonoscopy measurements than manual 3D or automated measurements. And automated measurement eliminated intraobserver and interobserver variability. For noninvasive CTC surveillance, manual 2D measurements are expected to measure medium-sized polyps with sufficient agreement with optical colonoscopic measurements and excellent intraobserver and interobserver variability, especially if combined with automated measurement.
Keywords:CT   colonography   CT colon   virtual colonoscopy
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号