Fatal Complications After Self-Expandable Metallic StentPlacement for Inferior Vena Cava Syndrome
Authors:Takuji?Yamagami  author-information"  >  author-information__contact u-icon-before"  >  mailto:yamagami@koto.kpu-m.ac.jp"   title="  yamagami@koto.kpu-m.ac.jp"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author,Toshiyuki?Nakamura,Yoko?Kin,Yukiko?Takimoto,Tsunehiko?Nishimura
Affiliation:(1) Department of Radiology, Kyoto Prefectural University of Medicine, Kyoto, Japan
Abstract:We present the case of a 71-year-old man withinferior vena cava syndrome due to metastatic lymph nodes fromhepatocellular carcinoma with serious complications that were stronglysuspected to result from rapid changes in hemodynamics afterself-expandable metallic stent placement.
Keywords:Venae cavae, flow dynamics  Venae cavae, grafts and prostheses  Venae cavae, interventional procedure  Venae cavae,stenosis or obstruction