1-Year Results of the ZEPHYR Registry (Zilver PTX for the Femoral Artery and Proximal Popliteal Artery): Predictors of Restenosis
Institution:1. Cardiovascular Center, Kansai Rosai Hospital, Amagasaki, Hyogo, Japan;2. Department of Metabolic Medicine, Osaka University Graduate School of Medicine, Osaka, Japan;3. Department of Diabetes Care Medicine, Osaka University Graduate School of Medicine, Osaka, Japan;4. Department of Cardiology, Kokura Memorial Hospital, Fukuoka, Japan;6. Division of Cardiology, Saiseikai Yokohama-City Eastern Hospital, Kanagawa, Japan;5. Cardiovascular Center, Kikuna Memorial Hospital, Yokohama, Kikuna, Japan;7. Cardiovascular Division, Department of Internal Medicine, Morinomiya Hospital, Osaka, Japan;11. Department of Advanced Cardiovascular Therapeutics, Osaka University Graduate School of Medicine, Osaka, Japan;12. Cardiovascular Center, Fukuoka Sanno Hospital, Fukuoka City, Japan
Abstract:ObjectivesThis study sought to assess the rate and predictors of 1-year restenosis after drug-eluting stent implantation for femoropopliteal (FP) lesions in patients with peripheral arterial disease.BackgroundZilver PTX, a paclitaxel-eluting stent for FP lesions, provides superior outcomes to angioplasty and bare-metal stents in clinical trials. However, its real-world outcomes and the associated features remain unclear.MethodsThis was a prospective multicenter study enrolling 831 FP lesions (797 limbs, 690 patients) treated by Zilver PTX implantation. The primary endpoint was 1-year restenosis. Secondary endpoints included major adverse limb event and stent thrombosis.ResultsMean lesion length was 17 ± 10 cm. One-year restenosis, major adverse limb event, and stent thrombosis rates were 37%, 22%, and 2%, respectively. The generalized linear mixed model showed that lesion length ≥16 cm assessed by angiography and distal external elastic membrane area ≤27 mm2 and minimum stent area ≤12 mm2 assessed by intravascular ultrasound were independent risk factors for restenosis. One-year restenosis rates were 15% in cases with none of these risk factors and 50% in those with ≥2 risk factors.ConclusionsThe current study demonstrated 1-year real-world outcomes after drug-eluting stent treatment for FP lesions, including challenging ones in clinical practice. Lesion length, external elastic membrane area, and minimum stent area were independent predictors for restenosis. (Zilver PTX for the Femoral Artery and Proximal Popliteal Artery—Prospective Multicenter Registry ZEPHYR]; UMIN000008433)
Keywords:drug-eluting stent  endovascular therapy  femoropopliteal lesion  intravascular ultrasound  restenosis  CI"}  {"#name":"keyword"  "$":{"id":"kwrd0030"}  "$$":[{"#name":"text"  "_":"confidence interval  DES"}  {"#name":"keyword"  "$":{"id":"kwrd0040"}  "$$":[{"#name":"text"  "_":"drug-eluting stent(s)  DUS"}  {"#name":"keyword"  "$":{"id":"kwrd0050"}  "$$":[{"#name":"text"  "_":"duplex ultrasonography  EEM"}  {"#name":"keyword"  "$":{"id":"kwrd0060"}  "$$":[{"#name":"text"  "_":"external elastic membrane  EVT"}  {"#name":"keyword"  "$":{"id":"kwrd0070"}  "$$":[{"#name":"text"  "_":"endovascular therapy  FP"}  {"#name":"keyword"  "$":{"id":"kwrd0080"}  "$$":[{"#name":"text"  "_":"femoropopliteal  IVUS"}  {"#name":"keyword"  "$":{"id":"kwrd0090"}  "$$":[{"#name":"text"  "_":"intravascular ultrasound  MALE"}  {"#name":"keyword"  "$":{"id":"kwrd0100"}  "$$":[{"#name":"text"  "_":"major adverse limb event  MSA"}  {"#name":"keyword"  "$":{"id":"kwrd0110"}  "$$":[{"#name":"text"  "_":"minimum stent area  ROC"}  {"#name":"keyword"  "$":{"id":"kwrd0120"}  "$$":[{"#name":"text"  "_":"receiver-operating characteristic  ST"}  {"#name":"keyword"  "$":{"id":"kwrd0130"}  "$$":[{"#name":"text"  "_":"stent thrombosis
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号