首页 | 本学科首页   官方微博 | 高级检索  
     


Comparison of in-hospital and long-term outcomes between a Cypher stent and a Taxus stent in Chinese diabetic patients with coronary artery disease
Authors:Yang Yue-jin  Xu Bo  Kang Sheng  Pei Wei-dong  Chen Ji-lin  Qiao Shu-bin  Qin Xue-wen  Yao Min  Chen Jue  Wu Yong-jian  Liu Hai-Bo  You Shi-Jie  Li Jian-Jun  Dai Jun  Gao Run-Lin
Affiliation:Coronary Heart Disease Center, Department of Cardiology,Cardiovascular Institute and Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
Abstract:Background The sirolimus and paclitaxel distribution patterns and tissue residence time may be modified in atherosclerotic lesions for patients with diabetes, and the biological mechanisms of action for these agents differ significantly. Previous clinical trials have yielded discrepant results of major adverse cardiac events and restenosis between a sirolimus-eluting stent and a paclitaxel-eluting stent in coronary artery disease. Therefore, this study was conduced to compare in-hospital and long-term clinical outcomes between patients receiving sirolimus-eluting stent (Cypher or Cypher Select stent) and paclitaxel-eluting stent (Taxus Express stent) after percutaneous intervention (PCI) in Chinese patients with diabetes. Methods One hundred and sixty-four consecutive diabetic patients underwent PCI in Fuwai Hospital from April 2004 to December 2004. Of them, 101 patients received Cypher or Cypher Select stents (Cypher group, 145 stents) and 63 patients received Taxus Express stents (Taxus group, 129 stents). Repeat coronary angiography was performed at 6-month and clinical outcomes were evaluated at 1- and 3-year follow-up. Stent thrombosis was classified according to Academic Research Consortium (ARC).Results The two groups did not differ significantly with respect to cardiac death, recurrent myocardial infarction (re-MI), target vessel revascularization (TVR) and occurrence of major adverse cardiac events (MACE). And the MACE-free cumulative survival at 1- and 3-year follow-up and early, late and very late thrombosis rates were also similar in the two groups (all P>0.05). There was a trend favoring PES over SES with regard to reducing cardiac death (0 vs 2.0%, P=0.524), re-MI (0 vs 2.0%, P=0.524), the composite of the cardiac death and re-MI (0 vs 4.0%, P=0.299) and very late thrombosis (0 vs 3.0%, P=0.295) between 1-year and 3-year follow-up.Conclusion The study indicates that PCI with either Cypher or Taxus stents is associated with similar efficacy and safety in the small population of Chinese diabetic patients during long-term follow-up.
Keywords:diabetes   percutaneous coronary intervention   stent   outcomes
本文献已被 维普 万方数据 PubMed 等数据库收录!
点击此处可从《中华医学杂志(英文版)》浏览原始摘要信息
点击此处可从《中华医学杂志(英文版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号