Sysmex XE2100血细胞分析仪与流式细胞检测抗体生成细胞的相关性
引用本文:郑军,白玉杰,孔岱,栾红.Sysmex XE2100血细胞分析仪与流式细胞检测抗体生成细胞的相关性[J].中国误诊学杂志,2010,10(2):253-255.
作者姓名:郑军  白玉杰  孔岱  栾红
作者单位:1. 中国医科大学附属一院检验科,辽宁,沈阳,110001
2. 辽宁省沈阳市第五人民医院检验科,110001
3. 辽宁中医药大学附属一院儿科,辽宁,沈阳,110001
摘    要:目的:通过对自身免疫性溶血性贫血(autoimmune hemolytic anemia,AIHA)患者抗体生成细胞(antibodysecreting cell,ASC)的检测,分析Sysmex XE2100分析仪与流式细胞仪的相关性及散点图的分布特征。方法:检测65例AIHA患者外周血白细胞并绘制SSC-SFL通道散点图;BD FACScalibur流式细胞仪检测ASC;显微镜分类计数200个白细胞中的ASC作为最终判定依据。结果:9个ASC/200WBC,流式细胞仪检测350个/μl,XE2100为级分布;1~6个ASC/200WBC,流式细胞仪检测100~300个/μl,XE2100为级分布;而在XE2100为级分布时,显微镜检查为阴性,流式细胞仪检测50个/μl左右。结论:检测ASC,流式细胞仪结果为最佳,而XE2100虽然不能准确定量,但其高速高可信度的分布图像是临床应用的重要补充。

关 键 词:血细胞计数/仪器和设备  抗体生成细胞

Relationship of Sysmex XE2100 and BD FACScalbur Flow Cytometry to Determine Antibody Secreting Cell in Periphery Blood of Patient with Autoimmune Hemolytic Anemia(AIHA)
ZHEN Jun,BAI Yu-jie,KONG Dai,et al..Relationship of Sysmex XE2100 and BD FACScalbur Flow Cytometry to Determine Antibody Secreting Cell in Periphery Blood of Patient with Autoimmune Hemolytic Anemia(AIHA)[J].Chinese Journal of Misdiagnostics,2010,10(2):253-255.
Authors:ZHEN Jun  BAI Yu-jie  KONG Dai  
Institution:ZHEN Jun,BAI Yu-jie,KONG Dai,et al.(Department of Lab.The First Hospital Affiliated to Chinese Medical University,Shenyang 110001,China)
Abstract:Objective:To analyse the pertinence relation of Sysmex XE2100 and BD FACScalbur flow cytometry to determine the antibody secreting cell in periphery blood of patient with autoimmune hemolytic anemia (AIHA). Method :To determine the ASC in periphery blood and draft SSC-SFL scatter graph with sysmex XE 2100,and analyse the ASC with BD FACScalicur flow cytometry and count the type I atypical lymphocyte with microscope. Results: 1-4 ASC/200WBC with microscope,1004300 ASC//*I with flow cytometry,mid density distribution with XE2100;〉6 ASC per high power field with microscope examination, 〉 350 ASC/μI with Flow cytornetry,high density distribution with XE2100 analyzer ;While there was tow density distribution with XE2100,it was negative results with micros-cope examination. But it was 50 ASC/μt with flow cytometry. Conclusion:For the determination of Asc,FCM is the best method. Although XE2100 is not quantitative determination method,it's the important plus for the high rate and high trustwor- thiness.
Keywords:Blood Cell Count/instrumentation  Antibody-Producing Cells  