Safety and efficacy of a 6 French perclose arterial suturing device following percutaneous coronary interventions: a pilot evaluation
Authors:Kornowski Ran  Brandes Simcha  Teplitsky Igal  Rechavia Eldad  Shor Nurit  Battler Alexander  Assali Abid
Affiliation:Cardiac Catheterization Laboratory, Cardiology Department, Rabin Medical Center, Petach Tikva, and Sackler Faculty of Medicine, Tel Aviv University, Israel. rkornowski@clalit.org.il
Abstract:BACKGROUND: Arterial access site management after percutaneous coronary intervention (PCI) is a matter of increasing importance in this era of potent antiplatelet pharmacotherapy. We evaluated the safety and efficacy of a 6 French (Fr) Perclose suturing device in achieving rapid hemostasis of the access site after PCI and thus improving patient comfort. METHODS: The 6 Fr Perclose (Prostar) device consists of a suture-based closure device delivered via introducer sheath designed for suturing of the arteriotomy puncture site. Over a 3-month period, the device was used in 48 consecutive PCI treated patients (age, 62 13 years; 70% male; 44% post myocardial infarction) and in-hospital groin complication rate was compared to 48 consecutive patients (age, 64 12 years; 64% male; 33% post myocardial infarction) who had manual compression hemostasis. RESULTS: Antiplatelet glycoprotein IIb/IIIa antagonists were used more frequently during and following the procedure in 58% of Perclose-treated patients versus 42% of the manual compression group (p = 0.019). Leg immobilization duration was 3 4 hours in all patients sutured by the device; in patients with manual compression, the sheath was removed at an average of 4.8 2.5 hours after termination of the PCI and an additional 6 hours of leg immobilization were subsequently required. No difference in overall major complication rate was found between groups (6.2% in suture-mediated patients versus 9.3% in manual compression group; p = 0.60). In 3 patients (6.2%) treated using the device, adjunctive manual compression was required in addition to groin suturing due to technical failure or residual oozing from the arteriotomy site. CONCLUSION: The 6 Fr Perclose device can be safely used to achieve rapid hemostasis and the device may hasten bed mobilization of PCI-treated patients despite frequent use of potent antiplatelet pharmacotherapy during coronary interventions.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号