Fatigue behaviour of dental composite materials
Authors:James L. Drummond  Lihong LinLulwa A. Al-Turki  Ryan K. Hurley
Affiliation:Department of Restorative Dentistry, University of Illinois at Chicago, Chicago, IL, USA
Abstract:

Objective

The intent of the project was to evaluate the fatigue behavior of particle and fiber filled dental composites that are fabricated either directly or indirectly using a notched specimen with respect to the number of cycles until failure.

Methods

The materials were five dental composites, three normally cured in the oral cavity (Restolux, Renew and Filtek Supreme), direct processing, and two laboratory produced (BelleGlass, and Tescera), indirect processing. The specimens were 3 mm × 3 mm × 25 mm bars with a 0.75 or 1.0 mm notch in the mid-span of the bars, polished with 320 grit SiC paper and aged for 6 months in air, distilled water, artificial saliva, and a 50/50 mixture of ethanol and distilled water. Testing was performed with a stress mean range of 5–49 MPa, the maximum number of cycles was 100,000, and the number of cycles to failure was recorded.

Results

For the specimens that failed, BelleGlass, Restolux, and Tescera were able to withstand a higher cyclic loaded stress than Renew and Filtek. The 50/50 by volume mixture of water and ethanol resulted in the lowest resistance to fatigue for all materials.

Conclusions

Of the dental composite materials investigated, the indirect processed and those with large particle fillers (higher weight percent filler) had better cyclic fatigue resistance than micro- and nano-particle fillers (lower weight percent filler).
Keywords:Dental composites   Cyclic loading   Aging   Fracture toughness