Determination of tissue plasminogen activator and its "fast" inhibitor in plasma
Authors:J Chmielewska  B Wiman
Abstract:We describe efficient, accurate methods for specific determination of tissue plasminogen activator (t-PA, EC 3.4.21.31) and its "fast" inhibitor in plasma. In this coupled assay, a sample containing t-PA is incubated with plasminogen, a plasmin (EC 3.4.21.7) substrate of low Km and high Kcat, and fibrin as a stimulator. The inhibitor of t-PA is determined by incubating the sample with a known amount of t-PA in excess, then determining the residual t-PA. Both t-PA and t-PA inhibitor can be determined in many samples simultaneously within a few hours. These assays are modifications of procedures described by us (Clin Chim Acta 1983;127:279-88 and Thromb Res 1983;31:427-36). Their accuracy as assessed by analytical recovery of pure t-PA added to blood samples (91 +/- 4%) or of partly purified inhibitor added to plasma samples (102 +/- 10%) is satisfactory, as is their precision. For the t-PA assay the CV was 1.6% (within run) or 4.1% (between run). The corresponding values for the inhibitor assay were 4.5% (within run) or 8.4% (between run) if the inhibitor concentration exceeded 3 arb. units/mL.