首页 | 本学科首页   官方微博 | 高级检索  
检索        

脑动静脉畸形的3D-CTA形态学评价
引用本文:陈衔城,吴劲松,陈爽,史玉泉,左长京,黄峰平.脑动静脉畸形的3D-CTA形态学评价[J].中华神经外科杂志,2001,17(2):91-94.
作者姓名:陈衔城  吴劲松  陈爽  史玉泉  左长京  黄峰平
作者单位:1. 上海医科大学附属华山医院神经外科
2. 上海医科大学附属华山医院放射科
3. 第二军医大学附属长海医院放射科
摘    要:目的 评价3D-CTA对脑动静脉畸形(AVM)的影像学诊断价值。方法23例AVM病例同时行3D-CTA与DSA检查,两者对照研究。结果 23例脑AVM术前3D-CTA检查阳性诊断率100%,无假阳性和假阴性。与DSA比较:(1)供血动脉的来源、数目和形态判断完全吻合;(2)引流静脉判断完全吻合19例(83%),部分吻合者4例(17%);(3)病灶部位判断完全吻合。无并发症发生。结论 脑AVM的3D-CTA二维影像与DSA基本吻合,立体空间三维形态描述好,可弥补后者不足,对手术有指导价值。本技术无创、低风险、价廉、其技术进一步成熟后可取代DSA。

关 键 词:脑动静脉畸形  数字减影血管造影  计算机断层扫描  CT
修稿时间:1999年5月10日

Preliminary evaluating the value of three-dimensional computed tomographic angiography in diagnosis of the morphology of intracranial arteriovenous malformations
CHEN Xiancheng,WU Jinsong,CHEN Shuang,et al..Preliminary evaluating the value of three-dimensional computed tomographic angiography in diagnosis of the morphology of intracranial arteriovenous malformations[J].Chinese Journal of Neurosurgery,2001,17(2):91-94.
Authors:CHEN Xiancheng  WU Jinsong  CHEN Shuang  
Institution:CHEN Xiancheng,WU Jinsong,CHEN Shuang,et al. Neurosurgery Department of Huashan Hospital,Shanghai Medical University,Shanghai 200040 China
Abstract:Objective To assess the value of three dimensional computed tomographic angiography (3D CTA) which used in the diagnosis of the morphotogy of intracranial arteriovenous malformations(AVMs). Methods A prospective evaluation within 2 years included 23 patients suspected of intracranial AVMs. All the patients underwent 3D CTA and digital subtraction angiography (DSA). Results The 3D CTA imaging provided excellent visualization of the intracranial AVMs. The false positive error and false negative error were not found. The details of arterial supply, size and location, which provided by 3D CTA images were exactly as the same as that in DSA, and the details of venous drainage were approxiamte match. Moreover, 3D CTA can provide a 3 D anatomy of AVMs and the relationship with adjacent structures, which can assist the surgeon to possible intropperative design. As a non invasive technique, there was no related complication . Conclusions 3D CTA provide similar 2 D images compare to images of DSA. Furthermore, it also supplies several advantages over DSA, in addition to reduced costs and avoidance of related complications. Preliminary data suggest that 3D CTA can partial replace catheter angiography inthe assessment of patients with intracranial AVMs. Although no firm conclusions or generalizations can be drawn from this limit cohort of patients, it is hoped that this report will stimulate interest and further study in both regions of technique and clinic.
Keywords:Intracranial arteriovenous malformations  Angiography  Digital subtraction  Tomography  X  Ray Computed
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号