Itraconazole suspension for intravenous injection: determination of the real component of complete refractive index for particle sizing by static light scattering
Authors:Wong Joseph  Papadopoulos Pavlos  Werling Jane  Rebbeck Christine  Doty Mark  Kipp James  Konkel Jamie  Neuberger Damian
Institution:Scientific Affairs, BioPharma Solutions, Baxter Healthcare Corporation, Round Lake, IL 60073, USA. joe_wong@baxter.com
Abstract:The purpose of this study is to assess the impact of real refractive indices, using different itraconazole suspensions, on the associated particle size distributions. Instrumental particle size measurement remains the practical option for determining the particle size distribution of a suspension. In this study, the suspension particle size distribution was measured by static light scattering, which requires knowledge of both the real and imaginary components of the complete refractive index. The real refractive indices of micronized itraconazole raw material, as well as vacuum-dried itraconazole suspension samples obtained from different formulations, polymorphs, manufacturing methods and particle size distributions, were determined using the Becke line method. Identical samples were analyzed by two contract laboratories in order to assess consistency. For the static light scattering equipment used in this study, the complete relative refractive index (RRI = n(particte) / n(dispersant) - ik) input required for software calculation is denoted by a refractive index kernel (RRI input) comprising a relative real component and an imaginary component. The reported real refractive indices for the itraconazole raw material as well as vacuum dried itraconazole suspension samples were different, ranging from 1.608 to 1.65 (selected kernel range of 120A010I to 124A010I). The imaginary component of itraconazole suspension was determined in a previous study to be 010I. The average real refractive index was calculated to be 1.62 (122A010I). The particle size distributions obtained using 120A010I and 124A010I were in good agreement with one generated using 122A010I. Therefore, itraconazole suspensions that were produced using different manufacturing methods/formulations or exhibited different particle size distributions/polymorphic forms may use 122A010I in determining particle size distribution. The particle size distributions determined using RRI input outside the range of 120A010I to 124A010I may not be reliable. However, it is recommended that similar investigations be conducted for other drug suspensions on a case-by-case basis.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号