Treatment of cutout of a lag screw of a dynamic hip screw in an intertrochanteric fracture
Authors:C C Wu  C H Shih  W J Chen  C L Tai
Institution:(1) Department of Orthopedics, Chang Gung Memorial Hospital, 5 Fu-Hsin St. 333, Kweishan, Taoyuan, Taiwan, TW
Abstract:Sixteen consecutive patients with cutout of a lag screw of a dynamic hip screw fixation in an intertrochanteric fracture were treated with reinsertion of a lag screw, bone cement supplementation in the neck-trochanter, and subtrochanteric valgus osteotomy. Postoperatively, patients were permitted to ambulate with protected weight-bearing. Fourteen patients were followed-up for at least 1 year (median 2 years; range 1–3 years), and all had a solid union. The union period took a median of 5 months, with a range of 3–7 months. Usually, union of an intertrochanteric fracture was faster than that of subtrochanteric osteotomy (P < 0.01). There were no complications of wound infection, loss of reduction, cutout of a lag screw, or osteonecrosis of the femoral head. From clinical and theoretical considerations, we conclude that despite cutout of a lag screw of a dynamic hip screw fixation being difficult to treat, out technique still can provide an excellent outcome. Therefore, we strongly recommend its wide use. Received: 7 February 1997