首页 | 本学科首页   官方微博 | 高级检索  
检索        


Retro-orbital injection is an effective route for radiopharmaceutical administration in mice during small-animal PET studies
Authors:Nanni Cristina  Pettinato Cinzia  Ambrosini Valentina  Spinelli Antonello  Trespidi Silvia  Rubello Domenico  Al-Nahhas Adil  Franchi Roberto  Alavi Abass  Fanti Stefano
Institution:Nuclear Medicine Department, Azienda Ospedaliero-Universitaria di Bologna Policlinico S. Orsola-Malpighi, Italy.
Abstract:BACKGROUND AND AIM: Small-animal PET is acquiring importance for pre-clinical studies. In rodents, radiotracers are usually administrated via the tail vein. This procedure can be very difficult and time-consuming as soft tissue extravasations are very frequent and tail scars can prevent repeated injections after initial failure. The aim of our study was to compare the retro-orbital (RO) versus tail vein intravenous (i.v.) administration of (18)F-FDG and (11)C-choline in mice for small-animal PET studies. METHODS: We evaluated four healthy female ICR CD1 mice according to the following protocol. Day 1: each animal underwent an i.v. injection of 28 MBq of (11)C-choline. PET scan was performed after 10 min and 40 min. Day 2: each animal received an RO injection of 28 MBq of (11)C-choline. A PET scan was performed after 10 min and 40 min. Day 3: each animal received an i.v. injection of 28 MBq of (18)F-FDG. A PET scan was performed after 60 min and 120 min. Day 4: each animal received an RO injection of 28 MBq of (18)F-FDG. A PET scan was performed after 60 min and 120 min. Administration and image acquisition were performed under gas anaesthesia. For FDG studies the animals fasted for 2 h and were kept asleep for 20-30 min after injection, to avoid muscular uptake. Images were reconstructed with 2-D OSEM. For each scan ROIs were drawn on liver, kidneys, lung, brain, heart brown fat and muscles, and the SUV was calculated. We finally compared choline i.v. standard acquisition to choline RO standard acquisition; choline i.v. delayed acquisition to choline RO delayed acquisition; FDG i.v. standard acquisition to FDG RO standard acquisition; FDG i.v. delayed acquisition to FDG RO delayed acquisition. RESULTS: The RO injections for both (18)F-FDG and (11)C-choline were comparable to the intravenous injection of F-FDG for the standard and delayed acquisitions. CONCLUSION: The RO administration in mice represents a technical advantage over intravenous administration in being an easier and faster procedure. However, its use requires high specific activity while its value in peptides and other receptor-specific radiopharmaceuticals needs further assessment.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号