首页 | 本学科首页   官方微博 | 高级检索  
     


Experimental and Numerical Studies on the Behaviors of Autoclaved Aerated Concrete Panels with Insulation Boards Subjected to Wind Loading
Authors:Junkai Lu  Jie Chen  Kun Zhu  Hang Xu  Wenjia Zhang  Qing Deng
Affiliation:1.School of Civil Engineering, Northeast Forestry University, Harbin 150040, China;2.China Construction Science and Industry Corporation, Shenzhen 518054, China; (J.C.); (H.X.);3.School of Civil Engineering, Changchun Institute of Technology, Changchun 130012, China;4.School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China;
Abstract:Autoclaved aerated concrete panels (AACP) are lightweight elements in civil engineering design. In this paper, experiments and numerical analyses were conducted to study the flexural behavior of an enclosure system that consisted of AACPs and a decorative plate. A full-scale test was conducted to investigate the behavior of the enclosure system under wind suction. Load–deflection curves and load–strain relationships under different wind pressures were recorded and discussed. The effects of thickness, reinforcement ratio, and strength grade on the flexural behavior of AACPs were numerically investigated. Based on the numerical results, we found that the flexural behavior of AACPs can be improved by increasing the thickness or the reinforcement ratio. A comparison of finite element and theoretical results calculated using American and Chinese design formulae was conducted, and the results indicated the existing design formulae can conservatively estimate the major mechanical indices of AACPs.
Keywords:AACPs   wind suction test   numerical simulation   mechanical property   flexural behavior
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号