首页 | 本学科首页   官方微博 | 高级检索  
检索        


Nearly two decades using the check-type to prevent ABO incompatible transfusions: one institution's experience
Authors:Figueroa Priscila I  Ziman Alyssa  Wheeler Christine  Gornbein Jeffrey  Monson Michael  Calhoun Loni
Institution:Department of Pathology and Laboratory Medicine, Division of Transfusion, Medicine, the Cleveland Clinic, Cleveland, OH 44195, USA.
Abstract:To detect miscollected (wrong blood in tube WBIT]) samples, our institution requires a second independently drawn sample (check-type CT]) on previously untyped, non-group O patients who are likely to require transfusion. During the 17-year period addressed by this report, 94 WBIT errors were detected: 57% by comparison with a historic blood type, 7% by the CT, and 35% by other means. The CT averted 5 potential ABO-incompatible transfusions. Our corrected WBIT error rate is 1 in 3,713 for verified samples tested between 2000 and 2003, the period for which actual number of CTs performed was available. The estimated rate of WBIT for the 17-year period is 1 in 2,262 samples. ABO-incompatible transfusions due to WBIT-type errors are avoided by comparison of current blood type results with a historic type, and the CT is an effective way to create a historic type.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏