Bare Stent Implantation Through a Side Slot of Another Stent in a Bifurcation Lesion
Authors:IOANNIS P ANTONELLIS  MD  SOTIRIOS P PATSILINAKOS  MD  CONSTANDINOS A PAMBOUCAS  MD  ANASTASIOS J SALACHAS  MD  ATHANASIOS J KRANIDIS  MD  NIKOLAOS G MARGARIS  MD  GEORGE P IFANTIS  MD  ANTONIOS G TAVERNARAKIS  MD  STYLIANOS G ROKAS  MD  
Institution:From the Invasive Cardiology Unit, Evangelismos Hospital;The Invasive Cardiology Unit, Alexandra Hospital, Athens, Greece
Abstract:A case of a patient with significant (≈ 90%) stenosis of the circumflex at its origin from the left main artery and of the first marginal branch, 20 mm after its origin from the circumflex, is described. The case was treated with implantation of two stents, one at the marginal and another at the circumflex through a side slot of the first stent.