首页 | 本学科首页   官方微博 | 高级检索  
     


Near-infrared spectroscopy monitoring during immediate transition after birth: time to obtain cerebral tissue oxygenation
Authors:Evelyn?Ziehenberger,Berndt?Urlesberger,Corinna?Binder-Heschl,Bernhard?Schwaberger,Nariae?Baik-Schneditz,Gerhard?Pichler  author-information"  >  author-information__contact u-icon-before"  >  mailto:gerhard.pichler@medunigraz.at"   title="  gerhard.pichler@medunigraz.at"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author  author-information__orcid u-icon-before icon--orcid u-icon-no-repeat"  >  http://orcid.org/---"   itemprop="  url"   title="  View OrcID profile"   target="  _blank"   rel="  noopener"   data-track="  click"   data-track-action="  OrcID"   data-track-label="  "  >View author&#  s OrcID profile
Affiliation:1.Research Unit of Neonatal Micro- and Macrocirculation, Department of Paediatrics,Medical University of Graz,Graz,Austria;2.Division of Neonatology, Department of Paediatrics,Medical University of Graz,Graz,Austria
Abstract:Feasibility of cerebral tissue oxygenation measurements immediately after birth has been published starting with first values 2 min after birth. Aim of this study was to evaluate, the time periods from birth and from arrival at the resuscitation table to obtain the first cerebral tissue oxygenation values with two different near infrared spectroscopy (NIRS) devices. The present study is an analysis of exploratory parameters of two prospective observational studies. Cerebral tissue oxygen saturation was measured by the NIRO 200NX measuring “cerebral-tissue-oxygenation-index” (cTOI) or the INVOS5100C measuring “cerebral-regional-oxygen-saturation” (crSO2). Four time periods (T) were defined: T1 birth to arrival at resuscitation table, T2 arrival to application of NIRS sensor, T3 application to first displayed cTOI or crSO2 value, and T4 from arrival at resuscitation table to first displayed values. Additionally, we compared first displayed values of cTOI and crSO2. Thirty neonates were included. Twenty-four were term and six late-preterm neonates. Fifteen neonates measured with NIRO were compared to 15 measured with INVOS. T1 was 49 (6–163) s with NIRO versus 59 (15–87) s with INVOS, T2 14 (4–20) s versus 12 (15–18) s, T3 33 (13–138) s versus 17 (6–290) s and T4 46 (20–153) s and 34 (14–300) s. The first displayed value tended to be higher for cTOI [54% (18–80)] compared to crSO2 [35% (15–87)]. There were no significant differences between devices in time periods and first values displayed. Cerebral tissue oxygenation can be measured within 1 min after arriving at the resuscitation table in term and preterm neonates after birth without difference between devices.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号