首页 | 本学科首页   官方微博 | 高级检索  
     


Automated SPECT analysis compared with expert visual scoring for the detection of FFR-defined coronary artery disease
Authors:R.?S.?Driessen,P.?G.?Raijmakers,I.?Danad,W.?J.?Stuijfzand,S.?P.?Schumacher,J.A.?Leipsic,J.?K.?Min,J.?Knuuti,A.?A.?Lammertsma,A.?C.?van?Rossum,N.?van?Royen,S.?R.?Underwood,P.?Knaapen  author-information"  >  author-information__contact u-icon-before"  >  mailto:p.knaapen@vumc.nl"   title="  p.knaapen@vumc.nl"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author
Affiliation:1.Department of Cardiology,VU University Medical Center,Amsterdam,The Netherlands;2.Department of Radiology & Nuclear Medicine,VU University Medical Center,Amsterdam,The Netherlands;3.Department of Radiology,St. Paul’s Hospital,Vancouver,Canada;4.Department of Radiology, Weill Cornell Medical College,New York-Presbyterian Hospital,New York,USA;5.Turku University Hospital and University of Turku,Turku,Finland;6.Department of Nuclear Medicine,Royal Brompton Hospital,London,UK
Abstract:

Purpose

Traditionally, interpretation of myocardial perfusion imaging (MPI) is based on visual assessment. Computer-based automated analysis might be a simple alternative obviating the need for extensive reading experience. Therefore, the aim of the present study was to compare the diagnostic performance of automated analysis with that of expert visual reading for the detection of obstructive coronary artery disease (CAD).

Methods

206 Patients (64% men, age 58.2?±?8.7 years) with suspected CAD were included prospectively. All patients underwent 99mTc-tetrofosmin single-photon emission computed tomography (SPECT) and invasive coronary angiography with fractional flow reserve (FFR) measurements. Non-corrected (NC) and attenuation-corrected (AC) SPECT images were analyzed both visually as well as automatically by commercially available SPECT software. Automated analysis comprised a segmental summed stress score (SSS), summed difference score (SDS), stress total perfusion deficit (S-TPD), and ischemic total perfusion deficit (I-TPD), representing the extent and severity of hypoperfused myocardium. Subsequently, software was optimized with an institutional normal database and thresholds. Diagnostic performances of automated and visual analysis were compared taking FFR as a reference.

Results

Sensitivity did not differ significantly between visual reading and most automated scoring parameters, except for SDS, which was significantly higher than visual assessment (p?p?p?p?=?0.063 and p?=?0.134). After optimization of the automated software, diagnostic accuracies were similar for visual (73.8%) and automated analysis. Among the automated parameters, S-TPD AC showed the highest accuracy (73.5%).

Conclusion

Automated analysis of myocardial perfusion SPECT can be as accurate as visual interpretation by an expert reader in detecting significant CAD defined by FFR.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏