首页 | 本学科首页   官方微博 | 高级检索  
     


Diagnostic performance of dual-energy CT for the detection of bone marrow oedema: a systematic review and meta-analysis
Authors:Chong?Hyun?Suh,Seong?Jong?Yun  author-information"  >  author-information__contact u-icon-before"  >  mailto:zoomknight@naver.com"   title="  zoomknight@naver.com"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author  author-information__orcid u-icon-before icon--orcid u-icon-no-repeat"  >  http://orcid.org/---"   itemprop="  url"   title="  View OrcID profile"   target="  _blank"   rel="  noopener"   data-track="  click"   data-track-action="  OrcID"   data-track-label="  "  >View author&#  s OrcID profile,Wook?Jin,Sun?Hwa?Lee,So?Young?Park,Chang-Woo?Ryu
Affiliation:1.Department of Radiology and Research Institute of Radiology, Asan Medical Center,University of Ulsan College of Medicine,Seoul,Republic of Korea;2.Department of Radiology, Kyung Hee University Hospital at Gangdong,Kyung Hee University School of Medicine,Seoul,Republic of Korea;3.Department of Radiology,Kyung Hee University,Seoul,Republic of Korea;4.Department of Emergency Medicine, Sanggye Paik Hospital,Inje University College of Medicine,Seoul,Republic of Korea
Abstract:

Objectives

The aim of this systematic review and meta-analysis was to assess the sensitivity and specificity of dual-energy CT (DECT) for the detection of bone marrow oedema (BME).

Methods

An electronic search of the PubMed and EMBASE databases was conducted. Bivariate modelling and hierarchical summary receiver-operating characteristic modelling were performed to evaluate the overall diagnostic performance of DECT for BME. Subgroup analysis was performed according to the assessment type (qualitative vs. quantitative) and anatomical location (spine vs. appendicular skeleton). Meta-regression analyses were performed according to the subject, study, and DECT characteristics.

Results

Twelve eligible studies (1901 lesions, 450 patients) were included. DECT exhibited a pooled sensitivity of 0.85 [95% confidence interval (CI): 0.78–0.90] and a pooled specificity of 0.97 (95% CI: 0.92–0.98) for BME detection. In addition, the diagnostic performance of qualitative assessment (sensitivity, 0.85; specificity, 0.97) was higher than that of quantitative assessment (sensitivity, 0.84; specificity, 0.88) of DECT findings. The diagnostic performance of DECT for the spine (sensitivity, 0.84; specificity, 0.98) and appendicular skeleton (sensitivity, 0.84; specificity, 0.93) were excellent. According to meta-regression analysis, the use of a tin filter, ≥ 2 image planes, and a slice thickness < 1 mm tended to exhibit higher sensitivity and hyperacute stage BME (< 24 h) tended to exhibit lower sensitivity.

Conclusions

These findings indicate that DECT has excellent sensitivity and specificity for BME detection. Qualitative assessment of DECT findings obtained using a tin filter, ≥ 2 image planes, and a 0.5-1-mm slice thickness in the acute stage BME (≥24 h) is recommended for more sensitive diagnosis.

Key Points

? Overall, DECT is useful for the detection of BME (sensitivity, 85%; specificity-97%). ? Qualitative assessment (sensitivity-85%; specificity-97%) is more accurate than quantitative assessment (sensitivity-84%; specificity-88%). ? DECT showed excellent diagnostic performance for both the spine/appendicular skeleton (sensitivity-84%/84%; specificity-98%/93%).
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号