首页 | 本学科首页   官方微博 | 高级检索  
     


High‐resolution diffusion tensor imaging of the human kidneys using a free‐breathing,multi‐slice,targeted field of view approach
Authors:Rachel W. Chan  Constantin Von Deuster  Christian T. Stoeck  Jack Harmer  Shonit Punwani  Navin Ramachandran  Sebastian Kozerke  David Atkinson
Affiliation:1. Centre for Medical Imaging, University College London, , London, UK;2. Institute for Biomedical Engineering, University and ETH Zurich, , Zurich, Switzerland;3. Division of Imaging Sciences, King's College London, , London, UK;4. Radiology Department, University College London Hospitals, , London, UK
Abstract:Fractional anisotropy (FA) obtained by diffusion tensor imaging (DTI) can be used to image the kidneys without any contrast media. FA of the medulla has been shown to correlate with kidney function. It is expected that higher spatial resolution would improve the depiction of small structures within the kidney. However, the achievement of high spatial resolution in renal DTI remains challenging as a result of respiratory motion and susceptibility to diffusion imaging artefacts. In this study, a targeted field of view (TFOV) method was used to obtain high‐resolution FA maps and colour‐coded diffusion tensor orientations, together with measures of the medullary and cortical FA, in 12 healthy subjects. Subjects were scanned with two implementations (dual and single kidney) of a TFOV DTI method. DTI scans were performed during free breathing with a navigator‐triggered sequence. Results showed high consistency in the greyscale FA, colour‐coded FA and diffusion tensors across subjects and between dual‐ and single‐kidney scans, which have in‐plane voxel sizes of 2 × 2 mm2 and 1.2 × 1.2 mm2, respectively. The ability to acquire multiple contiguous slices allowed the medulla and cortical FA to be quantified over the entire kidney volume. The mean medulla and cortical FA values were 0.38 ± 0.017 and 0.21 ± 0.019, respectively, for the dual‐kidney scan, and 0.35 ± 0.032 and 0.20 ± 0.014, respectively, for the single‐kidney scan. The mean FA between the medulla and cortex was significantly different (p < 0.001) for both dual‐ and single‐kidney implementations. High‐spatial‐resolution DTI shows promise for improving the characterization and non‐invasive assessment of kidney function. © 2014 The Authors. NMR in Biomedicine published by John Wiley & Sons, Ltd.
Keywords:human kidney  diffusion tensor imaging  targeted field of view  free breathing  multi‐slice imaging
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号