首页 | 本学科首页   官方微博 | 高级检索  
检索        


Use of color Doppler ultrasonography in the diagnosis of anomalous connection in pancreatobiliary disease
Authors:Kawashima Hiroki  Hirooka Yoshiki  Itoh Akihiro  Hashimoto Senju  Itoh Terutomo  Hara Kazuo  Kanamori Akira  Ohmiya Naoki  Niwa Yasumasa  Goto Hidemi
Institution:1. Department of Gastroenterology, Nagoya University Graduate School of Medicine, Nagoya 466-8550, Japan
2. Department of Endoscopy, Nagoya University Hospital, Nagoya 466-8550, Japan
Abstract:AIM: To estimate the detectability of anomalous connection in pancreatobiliary disease (ACPBD) cases, measuring gallbladder wall blood flow (GWBF). METHODS: In the retrospective study, we enrolled 42 subjects with gallbladder wall thickening. GWBF velocity was determined as an average value of the peak velocity of color signals on the gallbladder wall, three times in each case. Based on the findings on endoscopic ultrasonography (EUS) or endoscopic retrograde cholangiopancreatography (ERCP), the 42 subjects were divided into 11 cases with ACPBD and 31 cases without ACPBD. In the prospective study, the subjects were 92 cases with gallbladder wall thickening. Using the cut-off level of the flow velocity obtained in the retrospective study, the usefulness of measuring GWBF velocity in diagnosing ACPBD was evaluated. RESULTS: In the retrospective study, imaging of GWBF was obtained in 40 of the 42 subjects. The mean GWBF velocity of the ACPBD cases was 29.4+/-3.9 cm/s (mean+/-SD), which was significantly different (P<0.0001; 95% CI 5.48-13.2) from that of the without ACPBD cases (20.1+/-5.9 cm/s). Based on this result, we prepared a receiver operating characteristic curve, and the cut-off level appropriate for diagnosing ACPBD was estimated to be 25 cm/s. In the prospective study, GWBF was detected in 86 of the 92 subjects. Based on the EUS or ERCP findings, the 92 subjects were divided into 15 cases with ACPBD and 77 cases without ACPBD. When a cut-off level of 25 cm/s was employed, ACPBD could be diagnosed with a sensitivity of 87.0% (13/15) and a specificity of 87.3% (62/71). CONCLUSION: Measurement of GWBF velocity, which is less invasive and provides objective values, is very useful for diagnosing ACPBD prior to the development of malignant tumors in cases with gallbladder wall thickening.
Keywords:Color Doppler ultrasonography  Anomalous connection in pancreatobiliary disease  Gallbladder cancer  Gallbladder wall blood flow  Endoscopic ultrasonography  
本文献已被 CNKI 维普 万方数据 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号