首页 | 本学科首页   官方微博 | 高级检索  
检索        


A performance comparison of two (electro) chemiluminescence immunoassays for detection and quantitation of serum anti-spike antibodies according to SARS-CoV-2 vaccination and infections status
Authors:Jorge Camacho  Eliseo Albert  Joao Zulaica  Beatriz Álvarez-Rodríguez  Luciana Rusu  Beatriz Olea  María Jesús Alcaraz  Ron Geller  Estela Giménez  David Navarro
Institution:1. Microbiology Service, Clinic University Hospital, INCLIVA Health Research Institute, Valencia, Spain;2. Institute for Integrative Systems Biology (I2SysBio), Universitat de Valencia-CSIC, Valencia, Spain;3. Microbiology Service, Clinic University Hospital, INCLIVA Health Research Institute, Valencia, Spain

CIBERINFEC (Centro de investigación en red de enfermedades infecciosas), Instituto de Salud Carlos III, Madrid, Spain

Abstract:The information provided by SARS-CoV-2 spike (S)-targeting immunoassays can be instrumental in clinical-decision making. We compared the performance of the Elecsys® Anti-SARS-CoV-2 S assay (Roche Diagnostics) and the LIAISON® SARS-CoV-2 TrimericS IgG assay (DiaSorin) using a total of 1176 sera from 797 individuals, of which 286 were from vaccinated-SARS-CoV-2/experienced (Vac-Ex), 581 from vaccinated/naïve (Vac-N), 147 from unvaccinated/experienced (Unvac-Ex), and 162 from unvaccinated/naïve (Unvac-N) individuals. The Roche assay returned a higher number of positive results (907 vs. 790; p = 0.45; overall sensitivity: 89.3% vs. 77.6%). The concordance between results provided by the two immunoassays was higher for sera from Vac-N (ϰ: 0.58; interquartile ranges IQR]: 0.50−0.65) than for sera from Vac-Ex (ϰ: 0.19; IQR: −0.14 to 0.52) or Unvac-Ex (ϰ: 0.18; IQR: 0.06−0.30). Discordant results occurred more frequently among sera from Unvac-Ex (34.7%) followed by Vac-N (14.6%) and Vac-Ex (2.7%). Antibody levels quantified by both immunoassays were not significantly different when <250 (p = 0.87) or <1000 BAU/ml (p = 0.13); in contrast, for sera ≥1000 BAU/ml, the Roche assay returned significantly higher values than the DiaSorin assay (p < 0.008). Neutralizing antibody titers (NtAb) were measured in 127 sera from Vac-Ex or Vac-N using a S-pseudotyped virus neutralization assay of Wuhan-Hu-1, Omicron BA.1, and Omicron BA.2. The correlation between antibody levels and NtAb titers was higher for sera from Vac-N than those from Vac-Ex, irrespective of the (sub)variant considered. In conclusion, neither qualitative nor quantitative results returned by both immunoassays are interchangeable. The performance of both assays was found to be greatly influenced by the vaccination and SARS-CoV-2 infection status of individuals.
Keywords:antibodies  DiaSorin immunoassay  neutralizing antibodies  receptor binding domain antibodies  Roche immunoassay  SARS-CoV-2  S-trimeric antibodies
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号