首页 | 本学科首页   官方微博 | 高级检索  
     


Conventional sinus radiography compared with CT in the diagnosis of acute sinusitis
Authors:Aaløkken T M  Hagtvedt T  Dalen I  Kolbenstvedt A
Affiliation:Department of Radiology, Rikshospitalet, University of Oslo, N-0027 Oslo, Norway. trond.mogens.aalokken@rikshospitalet.no
Abstract:OBJECTIVES: To evaluate the value of plain film radiography in a prospective investigation of patients with clinical suspicion of acute sinusitis, using standard CT as a gold standard. METHODS: 47 consecutive patients were examined. Each patient underwent conventional X-ray and standard dose CT examinations on the same day. The sensitivity and specificity of the plain film examination were calculated. RESULTS: The specificity of the plain film examination was high, but the sensitivity was low except for the maxillary sinus (sensitivity 80%). Thus, for maxillary sinusitis, plain film examination was reasonably accurate. A negative finding in the other sinuses could not be relied upon. CONCLUSIONS: The sensitivity of plain film radiography for detecting sinus opacifications was unacceptably low for the ethmoid, frontal and sphenoid sinuses. The specificity was high.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏