首页 | 本学科首页   官方微博 | 高级检索  
检索        


Retrieval of a subintimal fractured guide wire from the brachial artery following saphenous vein graft stenting
Authors:Edward J Danson DPhil MA MRCP  Michael Ward FRACP PhD
Institution:Cardiology Department, Royal North Shore Hospital, New South Wales, Australia
Abstract:We present a case of a 58‐year‐old woman with diabetes mellitus with a history of angina, coronary artery bypass 24 years previously and who underwent retrieval of a fractured coronary buddy wire from the right brachial artery following attempted coronary intervention to a saphenous vein graft via the right radial route. Attempted removal of the guide wire had caused guide catheter‐induced dissection of the vein graft in addition to a distal stent edge dissection before fracture in the brachial artery. The fractured end of the buddy wire was found to be in the subintimal space and could only be retrieved by advancing the wire into the subclavian artery by means of wrapping its free portion around the guiding catheter. Its fractured end could then be snared into the guiding catheter but could only be withdrawn from behind the stented segment in the vein graft by means of a trap balloon in the guiding catheter. Successful stenting of a guide catheter‐induced dissection and distal stent edge dissection within the vein graft was then performed. This case highlights the hazards of deploying stents over buddy wires and of fractured guide wires in coronary intervention. © 2015 Wiley Periodicals, Inc.
Keywords:complications  saphenous vein grafts  PCI