BackgroundPassive and hybrid passive ankle foot orthoses (AFOs) are often prescribed in post stroke drop foot; however, the effects of these AFOs on balance related parameters in these patients seem unclear. Accordingly, the aim of current study was to evaluate the role of the newly designed hybrid passive and Posterior Leaf Spring (PLS) AFOs on balance related parameters including: self-reported balance confidence (ABC), Timed Up and Go Test (TUG) and Berg Balance Scale (BBS) in post stroke drop foot patients.MethodsFifteen post stroke drop foot patients were recruited in current study. Then, ABC, TUG and BBS were assessed with newly designed AFO and PLS AFO.ResultsThe results of this study were shown a significant improvement in ABC, TUG and BBS scores with the newly designed AFO than PLS AFO (p < 0.05).ConclusionThis study suggested that the newly designed AFO was improved the balance related parameters than PLS AFO. 相似文献
BackgroundAnteriorly-loaded walking is common in many occupations and may increase fall risk. Dynamic gait stability, defined by the Feasible Stability Region (FSR) theory, quantifies the kinematic relationship between the body’s center of mass (COM) and base of support (BOS). FSR-based dynamic gait stability has been used to evaluate the fall risk.Research questionHow does front load carriage affect dynamic gait stability, step length, and trunk angle among young adults during treadmill walking?MethodsIn this between-subject design study, 30 healthy young adults were evenly randomized into three load groups (0%, 10%, or 20% of body weight). Participants carried their assigned load while walking on a treadmill at a speed of 1.2 m/s. Body kinematics were collected during treadmill walking. Dynamic gait stability (the primary variable) was calculated for two gait events: touchdown and liftoff. Step length and trunk angle were measured as secondary variables. One-way analysis of variance was conducted to detect any group-related differences for all variables. Post-hoc analysis with Bonferroni correction was performed when main group differences were found.ResultsNo significant differences but medium to large effect sizes were found between groups for dynamic gait stability at touchdown (p = 0.194, η2 = 0.114) and liftoff (p = 0.122, η2 = 0.139). Trunk angle significantly increased (indicating backward lean) with the front load at touchdown (p < 0.001, η2 = 0.648) and liftoff (p < 0.001, η2 = 0.543). No significant between-group difference was found related to the step length (p = 0.344, η2 = 0.076).SignificanceCarrying a front load during walking significantly alters the trunk orientation and may change the COM-BOS kinematic relationship and, therefore, fall risk. The findings could inform the design of future studies focusing on the impact of anterior load carriage on fall risk during different locomotion. 相似文献
BackgroundRocker sole (RS) shoes have been linked to impaired postural control. However, which features of RS design affect balance is unclear.Research questionWhich RS design features affect standing balance and gait stability?MethodsThis study utilized an intervention and cross-over design. Twenty healthy young adults (10 males and 10 females) participated in this study. Standing balance and gait stability were measured using a single force platform and three-dimensional motion analysis system, respectively. The experimental conditions included the control shoe and five RS shoes in the combination of apex position (%) and apex angle (degree) for RS50-95, RS60-95, RS70-95, RS60-70, and RS60-110. The main outcome measures were the area surrounding the maximal rectangular amplitude, mean path length, average displacement of the center of pressure along the lateral and anterior/posterior directions, and maximal center of pressure excursion as the standing balance and lateral margin of stability as the gait stability. Statistical analyses were conducted using a two-way split-plot analysis of variance with repeated measures (with RS design as the within-subject factor and sex as the between-subject factor) and the Bonferroni post hoc test (α = .05).ResultsRegarding the mean path length, RS60-70 was significantly longer than the control shoe, and it showed a significantly increased lateral margin of stability. Thus, RS60-70 was shown to affect standing balance, limit of stability, and gait stability of the frontal plane during gait.SignificanceThese results suggest that the apex angle of the RS design feature affects standing balance and gait stability, and RS60-70 is detrimental to stability. Therefore, when RS with a small apex angle is prescribed, it is necessary to consider the patient’s balance ability. 相似文献
We report a case of benign lymphoplasmacytic plaque (LPP) in a child. These asymptomatic erythematous papulonodular lesions are an emerging clinicopathological entity. Herein, we describe a previously unreported site for LPP lesions, namely, the volar wrist and the distal ipsilateral palm. 相似文献
AKS-452 is a biologically-engineered vaccine comprising an Fc fusion protein of the SARS-CoV-2 viral spike protein receptor binding domain antigen (Ag) and human IgG1 Fc (SP/RBD-Fc) in clinical development for the induction and augmentation of neutralizing IgG titers against SARS-CoV-2 viral infection to address the COVID-19 pandemic. The Fc moiety is designed to enhance immunogenicity by increasing uptake via Fc-receptors (FcγR) on Ag-presenting cells (APCs) and prolonging exposure due to neonatal Fc receptor (FcRn) recycling. AKS-452 induced approximately 20-fold greater neutralizing IgG titers in mice relative to those induced by SP/RBD without the Fc moiety and induced comparable long-term neutralizing titers with a single dose vs. two doses. To further enhance immunogenicity, AKS-452 was evaluated in formulations containing a panel of adjuvants in which the water-in-oil adjuvant, Montanide™ ISA 720, enhanced neutralizing IgG titers by approximately 7-fold after one and two doses in mice, including the neutralization of live SARS-CoV-2 virus infection of VERO-E6 cells. Furthermore, ISA 720-adjuvanted AKS-452 was immunogenic in rabbits and non-human primates (NHPs) and protected from infection and clinical symptoms with live SARS-CoV-2 virus in NHPs (USA-WA1/2020 viral strain) and the K18 human ACE2-trangenic (K18-huACE2-Tg) mouse (South African B.1.351 viral variant). These preclinical studies support the initiation of Phase I clinical studies with adjuvanted AKS-452 with the expectation that this room-temperature stable, Fc-fusion subunit vaccine can be rapidly and inexpensively manufactured to provide billions of doses per year especially in regions where the cold-chain is difficult to maintain. 相似文献
Our aim was to evaluate the long-term skeletal stability of the mandible in 21 patients after orthognathic surgery with physiological positioning. The measurement points SNB, B point (X, Y), Pog (X, Y), and the angle of the ramus were measured on cephalometric photographs to assess skeletal stability preoperatively, immediately after operation, and one and two years postoperatively. In addition, we evaluated the clinical symptoms of disorders of the temporomandibular joint (TMJ). The analysis of the cephalometric photographs showed that SNB, B point X, and Pog X showed no significant differences among the postoperative time points. On the other hand, B point Y and Pog Y showed no significant differences throughout the study period. We compared the angle of the ramus before operation and two years postoperatively, and no significant difference was found. In addition, no cases showed any pathological symptoms of disorders of the TMJ two years postoperatively. The long-term stability after orthognathic surgery with physiological positioning was confirmed, and it seems to be a reliable orthognathic treatment in patients with mandibular prognathism. 相似文献
We evaluated RNA stability of Ebola virus in EDTA blood and urine samples collected from infected patients and stored in West Africa’s environmental conditions. In blood, RNA was stable for at least 18 days when initial cycle threshold values were <30, but in urine, RNA degradation occurred more quickly. 相似文献
Purpose: Spray-freeze drying (SFD) is a recently applied method to develop pharmaceutical powders. This study aimed to analyze the competence of Trehalose, Mannitol, Lactose, and Sorbitol instability and aerosolization of Immunoglobulin G (IgG) via SFD.
Methods: Induced soluble aggregates were quantified at 0 and 3?months, and 45?°C using size-exclusion chromatography. Conformation and thermogravimetric assessments were done by Fourier transform infrared spectroscopy and differential scanning calorimetry. Laser light scattering was performed to determine the particle sizes. Aerodynamic features were characterized by twin stage impinger and scanning electron microscopy.
Results: Although sugars/polyols preferably stabilized IgG following the process, storage stabilization was achieved in Trehalose, Trehalose-Lactose, Lactose, and Trehalose-Mannitol-based powders with soluble aggregates <5%. The conformation of antibody was preserved with β sheet content from 66.28% to 76.37%. Particle sizes ranged from 5.23 to 8.12?µm. Mannitol exhibited the best aerodynamic behavior, fine particle fraction (FPF: 70%) but high degree of protein aggregation during storage.
Conclusions: SFD could favorably stabilize antibody using Trehalose and its combination with Lactose and Mannitol, and also, Lactose alone. Sorbitol disturbed IgG powder recovery. Incorporation of other types of excipient is required for efficient respiratory delivery of IgG molecules. 相似文献