BackgroundUsing a mobile phone while performing a postural and locomotor tasks is a common, daily situation. Conversing or sending messages (SMS) while walking account for a significant share of accidental injuries. Therefore, understanding the consequences of using a mobile phone on balance and walking is important, all the more so when these postural and locomotor tasks are aggravated by a disease.Research questionOur objective was to conduct a scoping review on the influence of a dual-task situation – generated by the use of mobile phone – on users' postural and/or locomotor tasks.MethodsThe literature search was conducted in English on PubMed/Medline and CINHAL databases, using keywords associated with postural and locomotor tasks and with the use of mobile phone. Study location, population, number of subjects, experimental design, types of phone use, evaluated postural-locomotor tasks and expected effects were then analyzed.Results and significance46 studies were included in this work, 24 of which came from North America. All studies compared postural and locomotor tasks with and without the use of a smartphone. Ten studies also compared at least 2 groups with different characteristics. Only 4 studies included pathological subjects. Various modalities were tested, and most studies focused on walking. Results show that the use of smartphones slows down movement and induces a systematic imbalance, except when listening to music. The dual task of "using the smartphone during a postural or locomotor tasks" induces systematic disturbances of balance and movement, which must be taken into account in the rehabilitation approach. Future studies will have to extend the knowledge regarding pathological situations. 相似文献
BackgroundRocker sole (RS) shoes have been linked to impaired postural control. However, which features of RS design affect balance is unclear.Research questionWhich RS design features affect standing balance and gait stability?MethodsThis study utilized an intervention and cross-over design. Twenty healthy young adults (10 males and 10 females) participated in this study. Standing balance and gait stability were measured using a single force platform and three-dimensional motion analysis system, respectively. The experimental conditions included the control shoe and five RS shoes in the combination of apex position (%) and apex angle (degree) for RS50-95, RS60-95, RS70-95, RS60-70, and RS60-110. The main outcome measures were the area surrounding the maximal rectangular amplitude, mean path length, average displacement of the center of pressure along the lateral and anterior/posterior directions, and maximal center of pressure excursion as the standing balance and lateral margin of stability as the gait stability. Statistical analyses were conducted using a two-way split-plot analysis of variance with repeated measures (with RS design as the within-subject factor and sex as the between-subject factor) and the Bonferroni post hoc test (α = .05).ResultsRegarding the mean path length, RS60-70 was significantly longer than the control shoe, and it showed a significantly increased lateral margin of stability. Thus, RS60-70 was shown to affect standing balance, limit of stability, and gait stability of the frontal plane during gait.SignificanceThese results suggest that the apex angle of the RS design feature affects standing balance and gait stability, and RS60-70 is detrimental to stability. Therefore, when RS with a small apex angle is prescribed, it is necessary to consider the patient’s balance ability. 相似文献
ObjectiveWe aimed to establish an objective neurophysiological test protocol that can be used to assess the somatosensory nervous system.MethodsIn order to assess most fiber subtypes of the somatosensory nervous system, repetitive stimuli of seven different modalities (touch, vibration, pinprick, cold, contact heat, laser, and warmth) were synchronized with the electroencephalogram (EEG) and applied on the cheek and dorsum of the hand and dorsum of the foot in 21 healthy subjects and three polyneuropathy (PNP) patients. Latencies and amplitudes of the modalities were assessed and compared. Patients received quantitative sensory testing (QST) as reference.ResultsWe found reproducible evoked potentials recordings for touch, vibration, pinprick, contact-heat, and laser stimuli. The recording of warm-evoked potentials was challenging in young healthy subjects and not applicable in patients. Latencies were shortest within Aβ-fiber-mediated signals and longest within C-fibers. The test protocol detected function loss within the Aβ-fiber and Aδ-fiber-range in PNP patients. This function loss corresponded with QST findings.ConclusionIn this pilot study, we developed a neurophysiological test protocol that can specifically assess most of the somatosensory modalities. Despite technical challenges, initial patient data appear promising regarding a possible future clinical application.SignificanceEstablished and custom-made stimulators were combined to assess different fiber subtypes of the somatosensory nervous system using modality-specific evoked potentials. 相似文献
Objective: To assess the quality of images and video clips of fetal central nervous (CNS) structures obtained by ultrasound and transmitted via tele-ultrasound from Brazil to Australia.Methods: In this cross-sectional study, 15 normal singleton pregnant women between 20 and 26 weeks were selected. Fetal CNS structures were obtained by images and video clips. The exams were transmitted in real-time using a broadband internet and an inexpensive video streaming device. Four blinded examiners evaluated the quality of the exams using the Likert scale. We calculated the mean, standard deviation, mean difference, and p values were obtained from paired t tests.Results: The quality of the original video clips was slightly better than that observed by the transmitted video clips; mean difference considering all observers = 0.23 points. In 47/60 comparisons (78.3%; 95% CI?=?66.4–86.9%) the quality of the video clips were judged to be the same. In 182/240 still images (75.8%; 95% CI?=?70.0–80.8%) the scores of transmitted image were considered the same as the original.Conclusion: We demonstrated that long distance tele-ultrasound transmission of fetal CNS structures using an inexpensive video streaming device provided images of subjective good quality. 相似文献
Background: Before implementation of the new scale, the Swedish modified version of the Postural Assessment Scale for Stroke Patients (SwePASS), to clinical practice, it is fundamental to analyze its measurement properties.Objective: To examine the inter-rater reliability of the SwePASS in the acute phase after stroke.
Methods: Day 3 to day 7 after admission to a stroke unit, 64 persons with stroke were assessed twice, using the SwePASS, by two physiotherapists. Inter-rater reliability was determined using percentage-agreement and the rank-invariant method: relative position, relative concentration, and relative rank variance.
Results: The raters showed a percentage agreement of ≥75% in the assessments using the SwePASS. For 9 of the 12 items, the percentage agreement was >80%. For 8 of the 12 items, there was a statistically significant change in position, revealed in relative position values between 0.08 and 0.15. Three items had statistically significant positive relative concentration values between ?0.11 and 0.10. Except for a statistically significant negligible relative variance value of 0.01 for the items 1 and 8, there was no relative variance.
Conclusions: The SwePASS shows an acceptable inter-rater reliability, albeit with potential for improvement. The reliability can be improved by a consensus how to interpret the scale between the raters prior to implementation in the clinic. 相似文献
This study aimed at evaluating how encapsulation in a regular nanocarrier (NC) (providing extended circulation time) or in a brain-targeting NC (providing prolonged circulation time and increased brain uptake) may influence the therapeutic index compared with the unformulated drug and to explore the key parameters affecting therapeutic performance using a model-based approach. Pharmacokinetic (PK) models were built with chosen PK parameters. For a scenario where central effect depends on area under the unbound brain concentration curve and peripheral toxicity relates to peak unbound plasma concentration, dose-effect and drug-side effect curves were constructed, and the therapeutic index was evaluated. Regular NC improved the therapeutic index compared with the unformulated drug due to reduced peripheral toxicity, while brain-targeting NC enhanced the therapeutic index by lowering peripheral toxicity and increasing central effect. Decreasing drug release rate or systemic clearance of NC with drug still encapsulated could increase the therapeutic index. Also, a drug with shorter half-life would therapeutically benefit more from a NC encapsulation. This work provides insights into how a NC for brain delivery should be optimized to maximize the therapeutic performance and is helpful to predict if and to what extent a drug with certain PK properties would obtain therapeutic benefit from nanoencapsulation. 相似文献