Objective: To report a case of labour induction during extracorporeal membrane oxygenation (ECMO) support in a patient with acute respiratory distress syndrome (ARDS) caused by influenza and review of the literature.
Methods: Case report and the literature search of all English articles on delivery while on ECMO in patients with ARDS caused by influenza.
Results: A 25-year-old pregnant woman was initiated with ECMO due to severe ARDS caused by influenza A (H1N1) virus. When the patient had symptoms of colporrhagia and uterine contractions, the medical team decided to start labour induction while on ECMO. There were in total five case reports identified. Maternal oxygenation was improved after delivery and ECMO was successfully discontinued.
Conclusions: Maternal oxygenation was improved after delivery, which may be beneficial to reduce the duration of ECMO. Caesarean section (CS) may be the most used mode and labour induction could be another option. The procedure should be performed by an experienced ECMO team, cooperating with the obstetrician, anaesthesiologist, and ICU doctors. 相似文献
Summary Previous studies of Alcian blue-induced birefringence in adult avian cortical bone showed that a short period of intermittent
loading rapidly produces an increased level of orientation of proteoglycans within the bone tissue. In the absence of further
loading, this persists for over 24 hours. We have proposed that this phenomenon could provide a means for “capturing” the
effects of transient strains, and so provide a persistent, constantly updated strain-related influence on osteocyte populations
related to the bones' averaged recent strain history, in effect, a “strain memory” in bone tissue. In our present study, we
use the Alcian blue-induced birefringence technique to demonstrate that proteoglycan orientation also occurs after intermittent
loading of both cortical and cancellous mammalian bonein vivo andin vitro. We also show that the change in birefringence is proportional to the magnitude of the applied strain, and that the reorientation
occurs rapidly, reaching a maximal value after only 50 loading cycles. Examination of electron micrographs of bone tissue
after staining with cupromeronic blue allows direct visualization and quantification of the change in proteoglycan orientation
produced by loading. This shows that intermittent loading is associated with a realignment of the proteoglycan protein cores,
bringing them some 5 degrees closer to the direction of collagen fibrils in the bone matrix. 相似文献
RATIONALE AND OBJECTIVES: To compare hyperpolarized helium-3 (HHe) magnetic resonance imaging (MRI) of the lung with standard Xe-133 lung ventilation scintigraphy. MATERIALS AND METHODS: We performed a retrospective review of 15 subjects who underwent HHe MRI and Xe-133 lung ventilation imaging. Coronal MRI sections were acquired after a single inhalation of HHe gas, and standard posterior planar lung ventilation scintigraphy was performed during continuous breathing of Xe-133 gas. The first breath scintigram of each patient was compared with a composite MR image composed of the sum of the individual MR images and with the individual helium-3 MR images. Ventilation defects on the two imaging modalities were compared for size, conspicuity, and concordance in presence and location. Assessment was done separately for each of four lung quadrants. RESULTS: Comparing the composite HHe MR images with Xe-133 scintigraphy, ventilation defect size, conspicuity and concordance were the same in 67% (40/60), 63% (38/60), and 62% (37/60) quadrants, respectively. Comparing the individual HHe MR image sections with the Xe-133 ventilation scan, there was concordance between the ventilation defects in 27% (16/60) of quadrants. More defects were identified on the individual HHe MR images in 62% (37/60) of quadrants. CONCLUSION: There was good agreement between composite HHe MR image and first breath Xe-133 scintigraphic images, supporting the widely held assumption that HHe MRI likely depicts first breath lung ventilation. 相似文献
Failure of patient-triggered ventilation in very immature infants may be due to the use of inappropriate triggering systems. Two types of airflow trigger were therefore compared consecutively to an airway pressure (SLE) triggering system. Each comparison was made in 10 infants, ≤28 weeks of gestation. Comparison was made of the delivered volume, trigger performance and blood gases using each system for 1 h. Both comparisons showed that the airflow triggering systems performed better: one (Draeger Babylog 8000) had a higher sensitivity ( p < 0:01) and the other (Bird VIP airflow trigger), in which inflation was terminated by sensing a reduction in inspiratory flow, had a lower degree of asynchrony ( p < 0:01) and a tendency to deliver higher volumes. These results suggest that triggering systems sensing airflow changes may be superior to those sensing airway pressure changes in very immature infants. The use of a mechanism to synchronize the termination of inflation to the end of the patient's inspiration may offer further advantages. 相似文献