排序方式: 共有52条查询结果,搜索用时 125 毫秒
1.
目的探讨出非均匀磁场下的核磁共振技术条件。方法首先,分析开放式单边磁体非均匀主磁场的特点;其次,探讨CPMG单个衰减指数的回波与回波串幅度的包络线在非均匀场下的特性;最后,研究非均匀场下射频脉宽与带宽的限制条件。结果得出非均匀磁场下核磁共振技术条件,并通过仿真获得满足非均匀场条件下的CPMG信号。结论通过对CPMG序列下的非匀场核磁共振技术研究,并仿真验证了该技术条件的可行性,为后续单边全开放式磁体系统研究奠定基础。 相似文献
2.
The toxicological effects of realgar after intragastrical administration (1 g/kg body weight) were investigated over a 21 day period in male Wistar rats using metabonomic analysis of 1H NMR spectra of urine, serum and liver tissue aqueous extracts. Liver and kidney histopathology examination and serum clinical chemistry analyses were also performed. 1H NMR spectra and pattern recognition analyses from realgar treated animals showed increased excretion of urinary Kreb's cycle intermediates, increased levels of ketone bodies in urine and serum, and decreased levels of hepatic glucose and glycogen, as well as hypoglycemia and hyperlipoidemia, suggesting the perturbation of energy metabolism. Elevated levels of choline containing metabolites and betaine in serum and liver tissue aqueous extracts and increased serum creatine indicated altered transmethylation. Decreased urinary levels of trimethylamine-N-oxide, phenylacetylglycine and hippurate suggested the effects on the gut microflora environment by realgar. Signs of impairment of amino acid metabolism were supported by increased hepatic glutamate levels, increased methionine and decreased alanine levels in serum, and hypertaurinuria. The observed increase in glutathione in liver tissue aqueous extracts could be a biomarker of realgar induced oxidative injury. Serum clinical chemistry analyses showed increased levels of lactate dehydrogenase, aspartate aminotransferase, and alkaline phosphatase as well as increased levels of blood urea nitrogen and creatinine, indicating slight liver and kidney injury. The time-dependent biochemical variations induced by realgar were achieved using pattern recognition methods. This work illustrated the high reliability of NMR-based metabonomic approach on the study of the biochemical effects induced by traditional Chinese medicine. 相似文献
3.
Sturm VJ Basse-Lüsebrink TC Kampf T Stoll G Jakob PM 《Magnetic resonance in medicine》2012,68(2):507-515
Bloch-Siegert (BS) based B(1)(+) mapping methods use off-resonant pulses to encode quantitative B(1)(+) information into the signal phase. It was recently shown that the principle behind BS-based B(1)(+) mapping can be expanded from spin echo (BS-SE) and gradient-echo (BS-FLASH) based BS B(1)(+) mapping to methods such as Carr, Purcell, Meiboom, Gill (CPMG)-based turbo-spin echo (BS-CPMG-TSE) and multi-spin echo (BS-CPMG-MSE) imaging. If CPMG conditions are preserved, BS-CPMG-TSE allows fast acquisition of the B(1)(+) information and BS-CPMG-MSE enables simultaneous mapping of B(1)(+), M(0), and T(2). To date, however, two separate MRI experiments must be performed to enable the calculation of B(1)(+) maps. This study investigated a modified encoding strategy for CPMG BS-based methods to overcome this limitation. By applying a "bipolar" off-resonant BS pulse before the refocusing pulse train, the needed phase information was able to be encoded into different echo images of one echo train. Thus, this technique allowed simultaneous B(1)(+) and T(2) mapping in a single BS-CPMG-MSE experiment. To allow single-shot B(1)(+) mapping, this method was also applied to turbo-spin echo imaging. Furthermore, the presented modification intrinsically minimizes phase-based image artifacts in BS-CPMG-TSE experiments. 相似文献
4.
T. C. Basse‐Lüsebrink V. J. F. Sturm T. Kampf G. Stoll P. M. Jakob 《Magnetic resonance in medicine》2012,67(2):405-418
A novel method for B mapping based on the Bloch‐Siegert (BS) shift was recently presented. This method applies off‐resonant pulses before signal acquisition to encode B1 information into the signal phase. BS‐based methods possess significant advantages in measurement time and accuracy compared to magnitude‐based B methods. This study extends the idea of BS B mapping to Carr, Purcell, Meiboom, Gill (CPMG)‐based multi‐spin‐echo (BS‐CPMG‐MSE) and turbo‐spin‐echo (BS‐CPMG‐TSE) imaging. Compared to BS‐based spin echo imaging (BS‐SE), faster acquisition of the B information was possible using the BS‐CPMG‐TSE sequence. Furthermore, signal loss by T2* effects could be minimized using these spin echo‐based techniques. These effects are critical for gradient echo‐based BS methods at high field strengths. However, multi‐spin‐echo‐based BS B1 methods inherently possess high specific absorption rates. Thus, the relative specific absorption rate of BS‐CPMG‐TSE sequences was estimated and compared with the specific absorption rate produced by BS‐SE sequences. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc. 相似文献
5.
In this work, discrepancies between recent theories for susceptibility-induced T(2)-shortening and classical results, namely outer sphere theory and diffusion through local fields with random gradients, are considered. These discrepancies are assigned to the use of unrestricted diffusion in the new theories. 相似文献
6.
7.
8.
9.
J Zhou X Golay P C van Zijl M J Silvennoinen R Kauppinen J Pekar M Kraut 《Magnetic resonance in medicine》2001,46(2):401-406
T(2) of cortical gray matter is generally assumed to be longer than that of white matter. It is shown here that this is not the case in the occipital lobe, but that this effect is often obscured at lower resolution and concealed in standard T(2)-weighted images. Using a high-resolution (1 x 1.3 x 2 mm(3)) segmented EPI Carr-Purcell-Meiboom-Gill sequence, T(2) relaxation times of the brain were measured at 1.5 T for eight healthy adult volunteers. The average T(2) values of cortical gray and white matter were found to be 88 +/- 2 and 84 +/- 3 msec in the frontal lobe, 84 +/- 2 and 83 +/- 3 msec in the parietal lobe, and 79 +/- 1 and 87 +/- 3 msec in the occipital lobe, respectively. This unexpected occipital T(2) contrast between gray and white matter is attributed to regional differences in iron concentration. 相似文献
10.
A 3D Carr-Purcell-Meiboom-Gill (CPMG) sequence was implemented to obtain enhanced T(2) contrast in actively stained (perfusion with fixative and contrast agent) mouse brains at 9.4 T. Short interecho spacing was used to minimize diffusion and susceptibility losses. The sequence produced 16 3D volumes with an interecho spacing of 7 ms for isotropic 43-mu-resolution images of the mouse brains in a scan time of 4 hr. To enhance the signal-to-noise ratio (SNR) and contrast, the multiecho frequency domain image contrast (MEFIC) method was applied, resulting in a composite image with T(2)-weighted contrast. The high SNR and contrast thus achieved revealed aspects of mouse brain morphology, such as multiple cortical layers, groups of thalamic nuclei, layers of the inferior and superior colliculus, and molecular and granular layers of the cerebellum, with a high degree of definition and contrast that was not previously achieved in T(2)-weighted acquisitions at high fields. 相似文献