Sports Imaging has dramatically increased in the past decade with increasing number of adolescents, young and middle-aged adults participating in non-competitive/hobby sports. Therefore, sports injuries are no longer confined to elite athletes. Furthermore, newer forms of sports such as mountain climbing, pickle ball and curling etc. are gaining popularity. Majority of the injuries in sports medicine are from musculoskeletal trauma. Therefore, it is imperative that the musculoskeletal radiologist becomes familiar with various sports related injury patterns as these are commonly encountered in daily practice. This update aims to briefly encapsulate the major aspects of sports imaging. It includes the imaging manifestations of various types of musculoskeletal injuries on different modalities (commonly US and MRI) and briefly mentions the various image guided interventions, performed both on the sports field and in the hospital setting. 相似文献
ObjectiveTo present, the process of development and evaluation of an educational software on the Child Health Handbook proposed for the continuing education of primary care nurses and physicians.MethodsQuantitative study of methodological development. For software development, the following steps were followed: definition of objectives; determination of the target audience; choice of pedagogical and theoretical reference for content; content selection and structuring; software development and evaluation by experts (five nurses and four physicians). All responded to an instrument that included four domains: pedagogical; content; functionality; system presentation and usability. The evaluation criteria were arranged on a Likert-type scale. The percentage of agreement and Content Validity Index were used for the quantitative analysis of the degree of agreement, considering a Content Validity Index cutoff point equal to 0.80.ResultsThe overall agreement index, calculated by the arithmetic mean of the Contents Validity Index of the evaluated domains, was 0.96, with scores ranging from 0.90 to 1.00. The average percentage of agreement of the experts per domain was 92.86%, with lower agreement in the content (80.95%), presentation, and usability (90.48%) domains. 100% of percentage of agreement was observed in the pedagogical and functionality domains among the evaluated specialists.ConclusionThe percentage of agreement, Content Validity Index and overall agreement index of the Child Health Handbook educational software in the context of primary care disclosed the software adequacy as an educational resource for continuing education of primary care nurses and physicians. Considering the assessed dimensions, it can also be used by other health professionals and undergraduate students. 相似文献
PurposeAttempts by magnetic resonance (MR) manufacturers to help imaging centres improve patient throughput has led to the development of more automated acquisition. This software is capable of customizing individual scan alignment; potentially improving imaging efficiency and standardizing protocols. However, substantial investments are required to introduce such systems, potentially deterring their widespread application. This study assessed the implementation costs and reduction in examination durations for automated knee MR imaging (MRI) software.Materials and MethodsResearch activities were performed at a community-based academic centre on a 3-Tesla (3-T) system using Siemens' Day Optimizing Throughput (Dot) knee software. Examination acquisition times were extracted from the system before and after software implementation. Fiscal year 2012/13 finances were used to determine the average hourly cost of MRI utilization. Costs associated with automated software implementation were also calculated. Finally, the number of knee scans required to achieve a positive return on investment using the software was established.Results and DiscussionThe mean (standard deviation, sample size) pre- and post-Dot software scan times were 23.20 (4.18, n = 266) and 21.94 (4.51, n = 59) minutes, respectively, for a routine knee scan and 11.88 (1.60, n = 74) and 11.24 (1.51, n = 27) minutes, respectively, for a fast knee scan. The overall weighted average resulted in a 64-second time savings per automated knee examination. This negligible time savings would be extremely difficult to make use of clinically. Dot simplified 29 unique knee protocols to two, improving the consistency of knee examinations. Current Dot software is not compatible with all patients and therefore has limitations that are a concern among MR technologists.ConclusionAdoption of automated knee systems could assist in standardizing protocols; however, the cost of implementation and difficulty in modifying patient scheduling to reflect the minimal time savings would make a financial return unlikely to occur at small- and medium-sized institutions. 相似文献
Retinal fundus photographs are employed as standard diagnostic tools in ophthalmology. Serial photographs of the flow of fluorescein and indocyanine green (ICG) dye are used to determine the areas of the retinal lesions. For objective measurements of features, the registration of the images is a necessity. In this paper, we employ optimization techniques for registration with the help of 2-parameter translational motion model of retinal angiograms, based on non-linear pre-processing (Wiener filtering and morphological gradient) and computation of the similarity criteria for the alignment of the two gradient images for any given rigid transformation. The optimization methods are effectively employed to minimize the similarity criterion.
The presence of noise, the variations in the background and the temporal variation of the fluorescence level pose serious problems in obtaining a robust registration of the retinal images. Moreover, local search strategies are not robust in the case of ICG angiograms, even if one uses a multiresolution approach.
The present work makes a systematic comparison of different optimization techniques, namely the minimization method derived from the optical flow formulation, the Nelder-Mead local search and the HCIAC ant colony metaheuristic, each optimizing a similarity criterion for the gradient images. The impact of the resolution and median filtering of gradient image is studied and the robustness of the approaches is tested through experimental studies, performed on macular fluorescein and ICG angiographies.
Our proposed optimization techniques have shown interesting results especially for high resolution difficult registration problems. Moreover, this approach seems promising for affine (6-parameter motion model) or elastical registrations. 相似文献