BackgroundHepatic steatosis has been described as a common finding in adults following total pancreatectomy with islet autotransplantation (TPIAT) but it is unknown if this occurs in children and adolescents.ObjectivesTo define the frequency of post-TPIAT hepatic steatosis in a sample of children and adolescents and to identify clinical predictors of incident steatosis post-TPIAT.MethodsIn this prospective study, consecutive participants at least 1-month post-TPIAT underwent a liver MRI with proton density fat fraction (PDFF) and blood draw at our pediatric academic medical center between April 2021 and January 2022. Comparison clinical pre-TPIAT liver MRI or ultrasound and insulin use and graft function data were extracted from the medical record. T-tests were used for the comparison of means across continuous variables between participants with and without post-TPIAT steatosis.ResultsA total of 20 participants (mean: 13 ± 4 years; 12 female) were evaluated. Mean liver PDFF at research MRI was 7.4 ± 6.2% (range: 2–25%). Seven participants (35%) had categorical hepatic steatosis (PDFF>5%) post-TPIAT, five of whom had pre-TPIAT steatosis, reflecting a 13% (2/15; 95% CI: 2–40%) incidence of post-TPIAT steatosis. Participant characteristics were not significantly different between subgroups with and without post-TPIAT steatosis. Mean PDFF at research MRI was not different between graft function subgroups (7.5% optimal/good vs. 7.3% marginal/failure; p = .96).ConclusionOur study shows a moderate prevalence but low incidence of hepatic steatosis in a small sample of children and adolescents post-TPIAT. This study raises questions about a causal relationship between TPIAT and hepatic steatosis. 相似文献
This study investigated the hypocholesterolaemic effects of bitter melon aqueous extracts (BMAE) in vitro, the inhibitory effects of BMAE on pancreatic cholesterol esterase (CEase) and incorporation of cholesterol into micelles were investigated. BMAE decreased the in vitro micellar solubility of cholesterol in a dose-dependent manner. The conformation of CEase was investigated by means of circular dichroism (CD) and fluorescence. The result revealed the decrease of α-helix contents, increase of β-sheet and exposure of aromatic amino acid residuals. The incorporation of cholesterol into micelles was inhibited by BMAE. A complex was observed by transmission electron microscopy (TEM), which indicated interaction between cholesterol and BMAE. The result revealed that BMAE can play a role in decreased intestinal cholesterol absorption via inhibition of CEase, and of micelle formation. 相似文献
Three‐dimensional (3D) printing technology, virtual reality, and augmented reality technology have been used to help surgeons to complete complex total hip arthroplasty, while their respective shortcomings limit their further application. With the development of technology, mixed reality (MR) technology has been applied to improve the success rate of complicated hip arthroplasty because of its unique advantages. We presented a case of a 59‐year‐old man with an intertrochanteric fracture in the left femur, who had received a prior left hip fusion. After admission to our hospital, a left total hip arthroplasty was performed on the patient using a combination of MR technology and 3D printing technology. Before surgery, 3D reconstruction of a certain bony landmark exposed in the surgical area was first performed. Then a veneer part was designed according to the bony landmark and connected to a reference registration landmark outside the body through a connecting rod. After that, the series of parts were made into a holistic reference registration instrument using 3D printing technology, and the patient's data for bone and surrounding tissue, along with digital 3D information of the reference registration instrument, were imported into the head‐mounted display (HMD). During the operation, the disinfected reference registration instrument was installed on the selected bony landmark, and then the automatic real‐time registration was realized by HMD through recognizing the registration landmark on the reference registration instrument, whereby the patient's virtual bone and other anatomical structures were quickly and accurately superimposed on the real body of the patient. To the best of our knowledge, this is the first report to use MR combined with 3D printing technology in total hip arthroplasty. 相似文献
Polyethylene (PE) has been used extensively in knee arthroplasty since the mid 20th century. Progress in material manufacturing and processing has led to newer polyethylenes over last few decades with different material properties. It has been established that PE wear in knee arthroplasty causes particle induced osteolysis which is the main reason for late failure and requires revision surgery. Although there are various causes of wear, the properties of PE have long been a matter of investigation as a contributory factor. The advent of newer highly cross linked PE has been shown to improve wear rates in hip arthroplasty but the benefits have not been shown to be of the same degree in knee arthroplasty. The laboratory and clinical studies so far are limited and slightly conflicting in their conclusions. The risks of using highly cross linked PE in knee arthroplasty include tibial post fracture, disruption of locking mechanism, liner fracture which can lead to increased wear and osteolysis. The current evidence suggests that highly cross linked polyethylenes should be used with caution and only considered in younger active patients. The results of a recently completed randomized trial to compare the conventional with high molecular weight PE in knee arthroplasty are awaited. 相似文献
While use of large heads in total hip arthroplasty (THA) continues to grow, concerns have been raised regarding anterior hip pain resulting from impingement of the prosthetic head against soft-tissues like the iliopsoas. To address these concerns, a new anatomically contoured head (ACH) was developed. In this study cadaver tests were utilized to show that iliopsoas impingement/tenting caused by conventional heads is significantly relieved with the more rounded and reduced distal profile of the ACH. Thus, the ACH implant may be able to decrease the risk of soft-tissue impingement with conventional heads, particularly in the smaller hip. 相似文献
Objective: Longitudinal data on cardiometabolic effects of egg intake during adolescence are lacking. The current analyses aim to evaluate the impact of usual adolescent egg consumption on lipid levels, fasting glucose, and insulin resistance during late adolescence (age 17–20?years).
Methods: Data from 1392 girls, aged 9 to 10 at baseline and followed for 10?years, in the National Heart, Lung, and Blood Institute’s National Growth and Health Study were used to examine the association between usual egg intake alone and in combination with other healthy lifestyle factors and late adolescent lipid levels, fasting glucose, and insulin resistance, measured as homeostasis model assessment of insulin resistance (HOMA-IR). Diet was assessed using 3-day food records during eight examination cycles. Girls were classified according to usual weekly egg intake, ages 9–17?years:?<1 egg/wk (n?=?361), 1 to <3 eggs/wk (n?=?703), and ≥3 eggs/wk (n?=?328). Analysis of covariance modeling was used to control for confounding by other behavioral and biological risk factors.
Results: Girls with low, moderate, and high egg intakes had adjusted low-density lipoprotein cholesterol levels of 99.7, 98.8, and 95.5 mg/dL, respectively (p?=?0.0778). In combination with higher intakes of fiber, dairy, or fruits and vegetables, these beneficial effects were stronger and statistically significant. There was no evidence that ≥3 eggs/wk had an adverse effect on lipids, glucose, or HOMA-IR. More active girls who consumed ≥3 eggs/wk had the lowest levels of insulin resistance.
Conclusion: These results suggest that eggs may be included as part of a healthy adolescent diet without adverse effects on glucose, lipid levels, or insulin resistance. 相似文献