Background: Before implementation of the new scale, the Swedish modified version of the Postural Assessment Scale for Stroke Patients (SwePASS), to clinical practice, it is fundamental to analyze its measurement properties.Objective: To examine the inter-rater reliability of the SwePASS in the acute phase after stroke.
Methods: Day 3 to day 7 after admission to a stroke unit, 64 persons with stroke were assessed twice, using the SwePASS, by two physiotherapists. Inter-rater reliability was determined using percentage-agreement and the rank-invariant method: relative position, relative concentration, and relative rank variance.
Results: The raters showed a percentage agreement of ≥75% in the assessments using the SwePASS. For 9 of the 12 items, the percentage agreement was >80%. For 8 of the 12 items, there was a statistically significant change in position, revealed in relative position values between 0.08 and 0.15. Three items had statistically significant positive relative concentration values between ?0.11 and 0.10. Except for a statistically significant negligible relative variance value of 0.01 for the items 1 and 8, there was no relative variance.
Conclusions: The SwePASS shows an acceptable inter-rater reliability, albeit with potential for improvement. The reliability can be improved by a consensus how to interpret the scale between the raters prior to implementation in the clinic. 相似文献
OBJECTIVE: To prospectively determine the sonographic findings of nodular hyperplasia of the thyroid, to compare these with reported findings associated with malignancy, and to assess interobserver reliability. METHODS: Seventy thyroid nodules were scanned, and then biopsies of the nodules were performed under sonographic guidance with fine-needle cytologic analysis; in all cases images were reviewed by 2 experienced radiologists without knowledge of clinical outcome. Findings reported associated with malignancy were specifically assessed. Interobserver agreement between the expert and secondary readers for each finding was calculated by the kappa or weighted kappa statistic and the Fisher exact test of independence. RESULTS: There were 68 benign and 2 malignant nodules in a population of 63 female and 7 male patients. The mean benign nodule size was 2.9 cm; 60% were solid; 54% were hypoechoic; 59% were microlobulated or macrolobulated; 47% had central vascularity; 24% contained calcifications; and 82% were elliptical in shape. There was very good interobserver reliability for the presence of calcium (kappa = 0.91) and good agreement for the presence and location of vascularity (kappa = 0.75) and the amount of cystic components (kappa = 0.62; all P < .01). CONCLUSIONS: Sixty-nine percent of benign nodules had at least 1 finding reported previously as associated with malignancy. The interobserver reliability of the sonographic findings was good to very good for 3 of the 5 findings assessed. 相似文献
This paper reports an inter-rater reliability study on the Functional Independence Measure (FIM). The FIM measures inpatient burden of care, as reflected in 18 self care items, rated on a seven point scale from dependent to independent. The subjects were 40 occupational therapists, divided according to experience with the FIM and randomly assigned to a FIM training or non-training group. Subjects rated video tapes of four stroke patients on transfers, bathing, dressing, grooming, toileting and eating items from the FIM. Rater consensus was calculated using the intraclass correlation coefficient (ICC), percentage agreement and a measure of disagreement. Rating accuracy was measured by comparisons with an expert rater. Ratings were most reliable when done by clinicians with no prior FIM experience, from the FIM training group. It is strongly recommended that all clinicians undergo FIM training before using this tool to ensure acceptable reliability. 相似文献
Regulations evolve and risks management becomes one of the biomedical engineers' preoccupations. Thus, risks are various, and consequently it is difficult to identify, to manage and to bring them under control. Furthermore, regulations exist for sectors like healthcare technology monitoring, but it is not the same thing for instance for the risks linked to the maintenance. Thus regulation in the sector of maintenance evolves and the decree of the 1st July law of health safety is going to modify the biomedical environment. The goal of this work is to study the tools and the methods of risks management that have been used for several years in the industrial field and to use them for some biomedical equipment like monitors or IV pumps. These methods adapted to these equipment will allow us to determine some appropriate rules of maintenance. 相似文献
Abstract Several previous studies have evaluated the effects of 0.12% chlorhexidine digluconate (ChD) mouthrinses on plaque and gingival inflammation. However, previously, none have been based in general dental practices. The aim of this study was to evaluate the potential to conduct controlled periodontal clinical trials in co-operation with general dental practitioners (gdps). The project took place in 5 general dental practices in the South of England. 121 healthy subjects (24 at 4 sites and 25 at the 5th). aged 18-65 years, mean 35 ± 12) years participated in a double-blind, randomised study during which they received full mouth assessments for plaque and gingival bleeding at baseline, 6 and 12 weeks. 60 subjects were randomly asigned to use the 0.12% ChD mouth wash and 6i the placebo. The assessments were carried out by 5 gpds, who had previously achieved inter-examiner κ scores of 0.78–0.85 (mean 0.81) for the plaque index (PlI), and of 0.73–0.94 (mean 0.87) for a modified gingival index (mGI), and who maintained κ scores of 0.51–0.90 for PII and of 0.73–1.00 for mGI during the 12 months required to complete the study. 98 subjects (48 ChD and 50 placebo) completed the study. Even though the baseline levels of plaque and gingivitis were low, by week 12, mean whole mouth piaque score of the ChD mouthwash users had fallen from 1.33 at baseline to 0.96 and was significantly lower (p < 0.001) than for the placebo users, 1.31 at baseline to 1.13. Whole-mouth gingival bleeding score fell from 0.56 to 0.42 in the ChD mouthwash group but was unchanged (0.54–0.55) in the placebo group. A subsidiary data analysis which considered the effects at sites indicated that within these overall differences, the ChD users experienced almost 2× the reduction from plaque score 2 at baseline at proximal molar sites over a 12-week period (50.6% ChD versus 27.6% placebo). It was concluded that 0.12% ChD mouthwash reduced plaque accumulation fay 28% and gingival inflammation by 25% over a 12–week period, that it is feasible for a group of gdps to maintain high levels of inter–examiner consistency in the use of PlI and mGI, that it is also feasible to carry out such a multicentre study in general dental practice, and that the use of mean mouth scores per subject to analyse the effects of mouthrinses may well mask variations in response throughout the mouth. 相似文献
The aim of this study was to test the inter-rater reliability of a revised oral assessment guide (ROAG) for patients residing in a geriatric rehabilitation ward. A consecutive sample of 140 patients was recruited for the study. Oral assessments were performed for 133 newly admitted patients by one registered nurse (RN) during a period of six months. A dental hygienist (DH) carried out 103 oral assessments during the same half-year. For 66 patients, the RN and the DH performed independent assessments. There was an agreement between the RN and the DH in the majority of the independent assessments, except for tongue and teeth/dentures. The percentage agreement exceeded 80 percent. Inter-rater agreement measured by Cohen's Kappa coefficient ranged from moderate to very good and percentage agreement had a range of 58 to 91 percent. The agreement was highest in assessment of voice and swallowing (91%). Assessments of teeth and dentures seemed to be most difficult for the RN to evaluate. ROAG was found to be a clinically useful assessment tool. Additional education and training is needed to improve the reliability of the oral assessments and should include continuous support from a dental hygienist as well as a pictorial manual on how to use the ROAG. 相似文献
We assessed the inter-rater reliability of the 100-point International Cooperative Ataxia Rating Scale (ICARS). Three neurologists independently rated videotaped ICARS examinations of 22 subjects with genetically determined ataxias (spinocerebellar ataxia [SCA] Type 1 in 11; SCA Type 2 in 1; Friedreich's ataxia in 10) and 4 controls. Scores on live ICARS assessment had ranged from 0 to 7 for controls and 11 to 74 for ataxic subjects (clinically very mildly affected to wheelchair-bound). Inter-rater correlation was very high for the total score (Kendall's omega 0.994, 95% confidence interval, 0.988-0.997), and high to very high for each component subscore (0.791 for speech to 0.994 for posture/gait). All correlations were significant at P < 0.00001. The ICARS exhibits very high inter-rater reliability even without prior observer standardisation and is sensitive to a range of ataxia severities from very mild to severe. 相似文献